Back to Search
Start Over
Complications after 100 sessions of cone-beam computed tomography-guided lung radiofrequency ablation: a single-center, retrospective experience
- Source :
- International Journal of Hyperthermia, Vol 37, Iss 1, Pp 763-771 (2020)
- Publication Year :
- 2020
- Publisher :
- Taylor & Francis Group, 2020.
-
Abstract
- Objective To evaluate complications after consecutive 100 sessions of cone-beam computed tomography (CBCT)-guided radiofrequency ablation (RFA) of lung tumors Materials and methods A retrospective study was conducted from January 2016 and October 2018. All procedures were performed using a CBCT virtual navigation guidance system, combining three-dimentional CBCT, needle planning software, and real-time fluoroscopy. Complications were evaluated for each RFA session in 63 consecutive patients (31 male, 32 female; mean age 58.0 years) with 121 lung tumors who underwent 100 sessions of CBCT-guided lung ablation with an internally cooled RFA system. Complications were recorded using the Common Terminology Criteria of Adverse Events (CTCAE) 5.0. A major complication was defined as a grade 3 or 4 adverse event. Results There was no postprocedural mortality. The major and minor complication rates were 5% and 28%, respectively. The major complications were significant pulmonary hemorrhage (1%), large hemothorax requiring drainage (1%), pneumonia treated with antibiotics (2%), and delayed bronchopleural fistula (1%). The minor complications were pneumothorax (15%), hemoptysis (11%), and subcutaneous emphysema (2%). Of the 15 pneumothoraces, percutaneous catheter drainage was required in six sessions. Pneumothorax was more likely to occur if RFA was performed on two or more tumors at one session. Immediate, periprocedural and delayed complications were 23%, 9%, and 1%, respectively. Conclusion CBCT-guided RFA of lung tumors is a relatively safe procedure with acceptable morbidity.
- Subjects :
- Male
Cancer Research
Cone beam computed tomography
genetic structures
Physiology
Radiofrequency ablation
Computed tomography
complication
lung neoplasms
Single Center
030218 nuclear medicine & medical imaging
law.invention
03 medical and health sciences
0302 clinical medicine
law
Physiology (medical)
medicine
Medical technology
Humans
R855-855.5
Lung
Retrospective Studies
cone-beam computed tomography
virtual navigation guidance
medicine.diagnostic_test
business.industry
Cone-Beam Computed Tomography
Middle Aged
respiratory system
humanities
surgical procedures, operative
medicine.anatomical_structure
030220 oncology & carcinogenesis
Catheter Ablation
Female
radiofrequency ablation
business
Nuclear medicine
Subjects
Details
- Language :
- English
- ISSN :
- 14645157 and 02656736
- Volume :
- 37
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- International Journal of Hyperthermia
- Accession number :
- edsair.doi.dedup.....4010fe2b7da8f5e75708daece74f682c