High mass accuracy assay for trimethylamine N-oxide using stable-isotope dilution with liquid chromatography coupled to orthogonal acceleration time of flight mass spectrometry with multiple reaction monitoring
- Source :
- Analytical and bioanalytical chemistry. 408(3)
- Publication Year :
- 2015
-
Abstract
- Trimethylamine N-oxide (TMAO) has attracted interest as circulating levels have reported prognostic value in patients with cardiovascular conditions, such as heart failure. With continual advances in accurate mass measurements, robust methods that can employ the capabilities of time of flight mass spectrometers would offer additional utility in the analysis of complex clinical samples. A Waters Acquity UPLC was coupled to a Waters Synapt G2-S high-resolution mass spectrometer. TMAO was measured in plasma by stable-isotope dilution-hydrophilic interaction liquid chromatography-time of flight mass spectrometry with multiple reaction monitoring (LC-ToF-MRM). Two transitions were monitored: m/z 76.1 to 58.066/59.073 and m/z 85.1 to 66.116/68.130. The method was assessed for linearity, lower limits of detection and quantitation, and reproducibility. A selected cohort of patients with systolic heart failure (SHF; n = 43) and healthy controls (n = 42) were measured to verify the assay is suitable for the analysis of clinical samples. Quantitative analysis of TMAO using LC-ToF-MRM enabled linearity to be established between 0.1 and 75 μmol/L, with a lower limit of detection of 0.05 μmol/L. Relative standard deviations reported an inter-day variation of ≤20.8 % and an intra-day variation of ≤11.4 % with an intra-study quality control variation of 2.7 %. Run times were 2.5 min. Clinical application of the method reported that TMAO in SHF was elevated compared to that of healthy controls (p
- Subjects :
- Male
Spectrometry, Mass, Electrospray Ionization
Analytical chemistry
Indicator Dilution Techniques
Trimethylamine N-oxide
030204 cardiovascular system & hematology
Mass spectrometry
01 natural sciences
Biochemistry
High-performance liquid chromatography
Sensitivity and Specificity
Analytical Chemistry
Cohort Studies
03 medical and health sciences
chemistry.chemical_compound
Methylamines
0302 clinical medicine
Humans
Aged
Detection limit
Aged, 80 and over
Reproducibility
Chromatography
010401 analytical chemistry
Selected reaction monitoring
Oxides
Middle Aged
0104 chemical sciences
Time of flight
chemistry
Cardiovascular Diseases
Female
Quantitative analysis (chemistry)
Subjects
Details
- ISSN :
- 16182650
- Volume :
- 408
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- Analytical and bioanalytical chemistry
- Accession number :
- edsair.doi.dedup.....3fded86ae778d1c07242361d48e5017e