Back to Search Start Over

Experimental Validation of the Use of Cold Cathode Gauge inside the Cryomodule Insulation Vacuum

Authors :
Jenhani, Hassen
Carbonnier, Pol
Institut de Recherches sur les lois Fondamentales de l'Univers (IRFU)
Commissariat à l'énergie atomique et aux énergies alternatives (CEA)-Université Paris-Saclay
Source :
JACoW, 20th International Conference on RF Superconductivity, 20th International Conference on RF Superconductivity, Jun 2021, Online Conference, United States. pp.THPTEV011, ⟨10.18429/JACoW-SRF2021-THPTEV011⟩
Publication Year :
2022
Publisher :
JACoW Publishing, Geneva, Switzerland, 2022.

Abstract

The Proton Improvement Plan - II (PIP-II) project is underway at Fermilab with an international collaboration involving CEA in the development and testing of 650 MHz cryomodules. The risk analysis related to cryomodule operation proposed to add a vacuum gauge on the power coupler to prevent the untimely rupture of its ceramic. Due to the advanced design of the cryomodules, the gauge needs to be integrated inside the insulation vacuum to reduce the impact of this new modification. The lack of experience feedback on a similar operating condition requires an experimental validation before the implementation. This article details the experimental tests carried out before the approval of this solution.<br />Proceedings of the 20th International Conference on RF Superconductivity, SRF2021, East Lansing, MI, USA

Details

Language :
English
Database :
OpenAIRE
Journal :
JACoW, 20th International Conference on RF Superconductivity, 20th International Conference on RF Superconductivity, Jun 2021, Online Conference, United States. pp.THPTEV011, ⟨10.18429/JACoW-SRF2021-THPTEV011⟩
Accession number :
edsair.doi.dedup.....3ecfc9490c200b3b8d3a970dceabeda7
Full Text :
https://doi.org/10.18429/jacow-srf2021-thptev011