Back to Search Start Over

Effect of the structured packing height on efficiency of freons mixture separation in a large-scale model of distillation column

Authors :
N. I. Pecherkin
H. Sui
X. Li
Mingyan Liu
Aleksandr N. Pavlenko
Hong Li
A. D. Nazarov
Vladimir P. Zhukov
Source :
MATEC Web of Conferences, Vol 115, p 08003 (2017)
Publication Year :
2017
Publisher :
EDP Sciences, 2017.

Abstract

Results of experimental studies of heat-and-mass transfer and hydrodynamic processes at distillation on a regular packing are presented. The mixture of freons R114–R21 at the pressure of 0.3 MPa was used as a working mixture. The mixture was separated on the Mellapak 350Y structured packing with the diameter of 0.9 m under the conditions of complete reflux ( L/V = 1) at different packing heights. A specially designed liquid distributor with a possibility to change the density and pattern of drip points was used to irrigate the packing. The experimental data on the efficiency of mixture separation (height of transfer unit HTU ) and distribution of the local flow rate density over the column cross-section were compared. It is shown that an increase in the height of the structured packing from 2.1 m to 4.0 m leads to a significant decrease in the efficiency of mixture separation in the distillation column.

Details

Language :
English
Volume :
115
Database :
OpenAIRE
Journal :
MATEC Web of Conferences
Accession number :