Back to Search Start Over

A Multilevel Analysis of Platform-Switching Flapless Implants Placed at Tissue Level: 4-year Prospective Cohort Study

Authors :
Chiara Pirani
Fausto Zamparini
Lucio Montebugnoli
Carlo Prati
Luigi Canullo
Maria Giovanna Gandolfi
Prati C.
Zamparini F.
Pirani C.
Montebugnoli L.
Canullo L.
Gandolfi M.G.
Source :
The International journal of oralmaxillofacial implants. 35(2)
Publication Year :
2020

Abstract

Purpose: To evaluate the factors affecting peri-implant marginal bone level of single platform-switched implants with a smooth neck placed at gingival level (tissue level) using a flapless technique. Materials and Methods: Consecutive healthy patients requiring dental implant rehabilitations were enrolled in this study. Titanium implants with a zirconium-oxide-blasted surface and a platform-switch neck tulip configuration were used. Loading was performed 3 months after insertion with a provisional resin crown and after approximately 15 days with a definitive ceramic crown. Peri-implant marginal bone level (MBL) was measured on periapical radiographs at 1, 3, 6, 12, 24, 36, and 48 months by a blinded assessor. The following parameters were evaluated: location (maxillary/mandibular), position (anterior/posterior), sex (male/female), smoke (yes/no), implant placement timing (immediate, early, delayed), gingival thickness (thin/thick), endodontically treated adjacent teeth (yes/no), and diameter (3.8/4.25/5.0 mm). Multilevel analyses exploring factors associated with MBL at 36 and 48 months were performed. Results: A total of 76 patients (42 women, 34 men; mean age: 55.6 ± 10.7 years) received 128 implant rehabilitations. The survival rate was 98.4%. MBL displayed an initial increase during the first months from insertion (preload period). Cumulative mean MBL at T48 was 0.99 ± 0.68, which was not statistically significant from the values at T24 to T36 (P >.05). Mandibular location, delayed implants, and presence of adjacent endodontically treated teeth showed higher bone loss at 36 months (P .05). Conclusion: Platform-switched implants placed nonsubmerged with a flapless approach showed a reduced bone loss progression in the first 4 years, as MBL remained stable at longer times (36 and 48 months). Implants placed with early and immediate timing showed reduced bone loss compared with delayed implants.

Details

ISSN :
19424434
Volume :
35
Issue :
2
Database :
OpenAIRE
Journal :
The International journal of oralmaxillofacial implants
Accession number :
edsair.doi.dedup.....3db5ade34f752026ab8270c528320f5d