Back to Search Start Over

Utilization of front-face fluorescence spectroscopy for monitoring lipid oxidation during Lebanese Qishta aging

Authors :
Monzer Hamze
Mustapha Najib
Zaher Hallab
Romdhane Karoui
Karim Hallab
Nour-Eddine Chihib
Eliot Patrick Botosoa
Walid Hallab
Guillaume Delaplace
Université Libanaise
Unité Matériaux et Transformations - UMR 8207 (UMET)
Institut de Chimie du CNRS (INC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE)-Centrale Lille Institut (CLIL)
Institut Charles Viollette (ICV) - EA 7394 (ICV)
Université du Littoral Côte d'Opale (ULCO)-Université de Lille-Institut National de la Recherche Agronomique (INRA)-Université d'Artois (UA)-Institut Supérieur d'Agriculture
Centrale Lille-Institut de Chimie du CNRS (INC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Institut National de Recherche pour l’Agriculture, l’Alimentation et l’Environnement (INRAE)
Université d'Artois (UA)-Institut National de la Recherche Agronomique (INRA)-Université du Littoral Côte d'Opale (ULCO)-Institut Supérieur d'Agriculture-Université de Lille
Source :
LWT-Food Science and Technology, LWT-Food Science and Technology, Elsevier, 2020, LWT, 130, pp.109693. ⟨10.1016/j.lwt.2020.109693⟩, LWT-Food Science and Technology, 2020, LWT, 130, pp.109693. ⟨10.1016/j.lwt.2020.109693⟩
Publication Year :
2020
Publisher :
HAL CCSD, 2020.

Abstract

International audience; Front-face fluorescence spectroscopy technique coupled with chemometric tools was used for predicting the freshness state of a Lebanese dairy product called Qishta, stored up to 20 days. Acid, peroxide and thiobarbituric acid reactive substances (TBARS) values reached no more than 0.93 mg NaOH g−1 fat, 6.22 meq O2 Kg−1 fat, and 0.0313 mg malonaldehyde (MA) kg−1 sample, respectively, throughout the investigated storage time. In parallel, fluorescence emission spectra of tryptophan and riboflavin, and fluorescence excitation spectra of vitamin A were recorded and showed the highest fluorescence intensity for the Qishta samples aged of 20 days and the lowest intensity for the fresh ones. The primary and secondary indicators of lipid oxidation showed that Qishta can be stored for 20 days without any alteration despite the increase in the TBARS after 16 days of storage. Principal component analysis (PCA) applied on riboflavin emission spectra allowed better discrimination between Qishta samples with a clear distinction of those aged 20 days while some overlapping was noticed between samples aged below 16 days. A high correlation (R2 = 0.923) was observed between the peroxide value and the intensity of the riboflavin fluorescence recorded at 460 nm.

Details

Language :
English
ISSN :
00236438 and 10961127
Database :
OpenAIRE
Journal :
LWT-Food Science and Technology, LWT-Food Science and Technology, Elsevier, 2020, LWT, 130, pp.109693. ⟨10.1016/j.lwt.2020.109693⟩, LWT-Food Science and Technology, 2020, LWT, 130, pp.109693. ⟨10.1016/j.lwt.2020.109693⟩
Accession number :
edsair.doi.dedup.....3d843d1d5a5ee45caf180176c6bb5d7e