Back to Search
Start Over
Selvester scoring in patients with strict LBBB using the QUARESS software
- Source :
- Journal of Electrocardiology. 48:763-768
- Publication Year :
- 2015
- Publisher :
- Elsevier BV, 2015.
-
Abstract
- Background Estimation of the infarct size from body-surface ECGs in post-myocardial infarction patients has become possible using the Selvester scoring method. Automation of this scoring has been proposed in order to speed-up the measurement of the score and improving the inter-observer variability in computing a score that requires strong expertise in electrocardiography. In this work, we evaluated the quality of the QuAReSS software for delivering correct Selvester scoring in a set of standard 12-lead ECGs. Method Standard 12-lead ECGs were recorded in 105 post-MI patients prescribed implantation of an implantable cardiodefibrillator (ICD). Amongst the 105 patients with standard clinical left bundle branch block (LBBB) patterns, 67 had a LBBB pattern meeting the strict criteria. The QuAReSS software was applied to these 67 tracings by two independent groups of cardiologists (from a clinical group and an ECG core laboratory) to measure the Selvester score semi-automatically. Using various level of agreement metrics, we compared the scores between groups and when automatically measured by the software. Results The average of the absolute difference in Selvester scores measured by the two independent groups was 1.4 ± 1.5 score points, whereas the difference between automatic method and the two manual adjudications were 1.2 ± 1.2 and 1.3 ± 1.2 points. Eighty-two percent score agreement was observed between the two independent measurements when the difference of score was within two point ranges, while 90% and 84% score agreements were reached using the automatic method compared to the two manual adjudications. Conclusion The study confirms that the QuAReSS software provides valid measurements of the Selvester score in patients with strict LBBB with minimal correction from cardiologists.
- Subjects :
- medicine.medical_specialty
Software Validation
Bundle-Branch Block
Absolute difference
Sensitivity and Specificity
Severity of Illness Index
Pattern Recognition, Automated
Electrocardiography
Software
Internal medicine
Humans
Medicine
In patient
Diagnosis, Computer-Assisted
Observer Variation
medicine.diagnostic_test
business.industry
Left bundle branch block
Reproducibility of Results
medicine.disease
Infarct size
Cardiology
Core laboratory
Cardiology and Cardiovascular Medicine
business
Algorithms
Subjects
Details
- ISSN :
- 00220736
- Volume :
- 48
- Database :
- OpenAIRE
- Journal :
- Journal of Electrocardiology
- Accession number :
- edsair.doi.dedup.....3cb3987b1ee4780783c48beaac3131e7
- Full Text :
- https://doi.org/10.1016/j.jelectrocard.2015.06.003