Back to Search
Start Over
Accuracy of detection of myocardial viability and residual infarct vessel stenoses with rest Tl-201 and adenosine Tc-99m sestamibi imaging after coronary reperfusion in dogs with experimental acute myocardial infarction
- Source :
- Journal of Nuclear Cardiology. 10:375-384
- Publication Year :
- 2003
- Publisher :
- Springer Science and Business Media LLC, 2003.
-
Abstract
- We sought to determine whether a dual-isotope imaging strategy (rest thallium 201/stress technetium 99m sestamibi) might be useful for assessing myocardial viability and residual ischemia in the infarct zone very early after reperfusion.Fifteen open-chest dogs had left anterior descending coronary artery occlusion for 60 minutes, followed by full reperfusion (group 1, n = 8) or reperfusion through a residual critical stenosis (group 2, n = 7). Tl-201 was injected at rest 45 minutes after reperfusion, and initial and 2-hour redistribution images were acquired. Tc-99m sestamibi was then injected during vasodilator stress, followed by imaging. Infarct size was similar in both groups (risk area, 21% +/- 4% vs 22% +/- 3%). Rest Tl-201 defect count ratios (left anterior descending coronary artery/left circumflex artery) were comparable (0.71 +/- 0.03 vs 0.74 +/- 0.02) and reflected infarct size. With vasodilation, Tc-99m sestamibi defect count ratio in group 1 (0.71 +/- 0.02) was comparable to rest Tl-201 and was significantly greater than in group 2 (0.62 +/- 0.02) with residual stenoses (P.01). Although vasodilator Tc-99m sestamibi imaging unmasked the presence of residual stenoses, Tc-99m sestamibi uptake underestimated their functional severity (flow ratio, 0.38 +/- 0.03).Dual-isotope imaging very early after reperfusion may have limited utility for detecting residual stenoses in the infarct zone. Underestimation of the flow disparity by Tc-99m sestamibi may make the detection of stenoses more difficult, and impaired flow reserve after ischemic insult may complicate the detection of fully reperfused segments.
- Subjects :
- Technetium Tc 99m Sestamibi
medicine.medical_specialty
Myocardial Infarction
Ischemia
chemistry.chemical_element
Myocardial Reperfusion Injury
Sensitivity and Specificity
Dogs
Reperfusion therapy
Internal medicine
medicine
Animals
Radiology, Nuclear Medicine and imaging
cardiovascular diseases
Myocardial infarction
Thallium
Radionuclide Imaging
Myocardial Stunning
Tissue Survival
Myocardial stunning
business.industry
Coronary Stenosis
Reproducibility of Results
Coronary flow reserve
Electrocardiography in myocardial infarction
Image Enhancement
medicine.disease
chemistry
cardiovascular system
Cardiology
Radiopharmaceuticals
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 10713581
- Volume :
- 10
- Database :
- OpenAIRE
- Journal :
- Journal of Nuclear Cardiology
- Accession number :
- edsair.doi.dedup.....3ba6f106b8e4dc52d02dd027284ab5c6
- Full Text :
- https://doi.org/10.1016/s1071-3581(03)00527-0