Back to Search
Start Over
Development and validation of a new high-performance liquid chromatographic estimation method of meloxicam in biological samples
- Source :
- Journal of chromatography. B, Biomedical sciences and applications. 738(2)
- Publication Year :
- 2000
-
Abstract
- A simple, HPLC method was developed to estimate meloxicam (COX-2 inhibitor) using piroxicam as the internal standard. The mobile phase containing methanol, acetonitrile and an aqueous solution of diammonium hydrogenorthophosphate (50 mM) in the ratio of 4:1:5 was pumped at the rate 1 ml/min. Lichrocart RP-18 (125 x 4 mm) was used as an analytical column and the analytes were detected at 364 nm using a UV detector. Acidified plasma samples were extracted with chloroform, evaporated to dryness, reconstituted in the mobile phase and then a volume of 10 microl of the prepared sample was injected in the column. The retention time of meloxicam and piroxicam was found to be 2.7 and 1.9, respectively. This method showed an accuracy of 102.3% at 0.52 microg/ml and was capable of detecting a minimum concentration of 0.029 microg/ml meloxicam from biological samples. The analytical method was successfully utilized for estimating meloxicam in biological samples.
- Subjects :
- Male
Analyte
Thiazines
Piroxicam
Meloxicam
High-performance liquid chromatography
Sensitivity and Specificity
chemistry.chemical_compound
medicine
Animals
Cyclooxygenase Inhibitors
Rats, Wistar
Chromatography, High Pressure Liquid
Chloroform
Aqueous solution
Chromatography
Extraction (chemistry)
General Chemistry
Reference Standards
Rats
Thiazoles
chemistry
Spectrophotometry, Ultraviolet
Quantitative analysis (chemistry)
medicine.drug
Subjects
Details
- ISSN :
- 13872273
- Volume :
- 738
- Issue :
- 2
- Database :
- OpenAIRE
- Journal :
- Journal of chromatography. B, Biomedical sciences and applications
- Accession number :
- edsair.doi.dedup.....3b3ed05b4b7009dff097f36fe6533b6a