Back to Search Start Over

Image quality and radiation dose in 256-slice cardiac computed tomography: Comparison of prospective versus retrospective image acquisition protocols

Authors :
Tobias Heye
Stephanie Lehrke
Waldemar Hosch
Felix Schulz
Evangelos Giannitsis
Martin Schlieter
Grigorios Korosoglou
Hans-Ulrich Kauczor
Hugo A. Katus
Source :
European Journal of Radiology. 80:127-135
Publication Year :
2011
Publisher :
Elsevier BV, 2011.

Abstract

To assess coronary artery image quality and patient radiation exposure in patients who underwent clinically indicated 256-slice CTA.Consecutive patients (n=193) underwent 256-slice CTA, using (1) retrospective gating without radiation dose modulation, (2) retrospective gating with radiation dose modulation and (3) prospective gating. Image quality was determined by consensus of two experienced observers using a 5-grade scale. The effective dose was calculated.In all patients, CTA was performed without adverse events. Retrospective CTA was assessed in 39 patients with and 39 without dose modulation, while 115 patients underwent prospective CTA. Heart rate was related to image quality with all protocols (r=0.46, p0.001). Up to a heart rate of 75 bpm no significant difference in overall image quality was observed for all three protocols, while no significant differences could be observed between retrospective CTA with and without dose modulation for any segments or heart rates. Prospective and retrospective CTA with dose modulation showed radiation savings of ∼75 % and ∼30 %, respectively compared to retrospective CTA without dose modulation (p0.001).In patients with heart rates up to 75 bpm prospective CTA should be the first choice acquisition protocol. For heart rates75 bpm, retrospective CTA with dose modulation should be considered.

Details

ISSN :
0720048X
Volume :
80
Database :
OpenAIRE
Journal :
European Journal of Radiology
Accession number :
edsair.doi.dedup.....3ad804ea92d98381c92e09d48f47baf5
Full Text :
https://doi.org/10.1016/j.ejrad.2010.07.011