Back to Search Start Over

Do crosslinking and vitamin E stabilization influence microbial adhesions on UHMWPE-based biomaterials?

Authors :
Elena Maria Brach Del Prever
Giuliana Banche
A. Cimino
Pierangiola Bracco
Valeria Allizond
Michele Boffano
Annamaria Cuffini
Alessandro Bistolfi
Source :
Clinical orthopaedics and related research. 473(3)
Publication Year :
2014

Abstract

Microorganism adhesion on polyethylene for total joint arthroplasty is a concern. Many studies have focused on vitamin E-stabilized ultrahigh-molecular-weight polyethylene (UHMWPE), whereas first-generation, highly crosslinked UHMWPE, which is the most commonly used in clinical practice, has been scarcely evaluated.We aimed (1) to compare the adherence of Staphylococcus epidermidis, Staphylococcus aureus, Escherichia coli, and Candida albicans with virgin (untreated) UHMWPE (PE) and crosslinked UHMWPE (XLPE); (2) to correlate the results with the biomaterial surface properties; and (3) to determine whether the decreased adhesion on vitamin E-stabilized UHMWPE (VE-PE) previously recorded for bacteria can also be confirmed for C albicans.Microbial adhesion of biofilm-producing American Type Culture Collection (ATCC) and clinical strains on XLPE and VE-PE were compared with PE at 3, 7, 24, and 48 hours of incubation and quantified, as colony forming units (CFU)/mL, using a sonication protocol. Sample surfaces were characterized by scanning electron microscopy, roughness and contact angle measurements, attenuated total reflection-Fourier transform infrared spectroscopy, and x-ray photoelectron spectroscopy (XPS) to reveal qualitative differences in surface composition and topography that could influence the microbial adhesion. The results were analyzed by descriptive statistics and tested by unpaired t-tests.All microorganisms, both ATCC and clinical strains, showed lower adhesion (p0.05) on XLPE with adhesion percentages ranging from 18% to 25%, compared with PE with adhesion percentages ranging from 51% to 55%, after 48 hours. Only the ATCC S epidermidis showed a reduced adhesion profile even at 3 hours (adhesion ratio of 14% on XLPE versus 50% on PE) and 24 hours (19% on XLPE versus 55% on PE) of incubation. ATCC and clinical C albicans were less adherent to XLPE than to PE (p0.05) showing even at the earlier incubation time points adhesion values always of 10(3) CFU/mL and 10(4) CFU/mL, respectively. Roughness and contact angle were 0.8 ± 0.2 μm and 92° ± 3°, respectively, with no differences among samples. Qualitative differences in the surface chemical composition were revealed by XPS only. A confirmation of the decreased adhesion on VE-PE respect to PE was also registered here for C albicans strains (p0.05).Vitamin E stabilization and crosslinking of UHMWPE are capable of reducing microbial adhesion. Further studies are needed to fully elucidate the mechanisms of modulation of microbial adhesion to medical-grade UHMWPE.Our results suggest that VE-PE and XLPE may have an added benefit of being more resistant to bacterial adhesion, even fungal strains.

Details

ISSN :
15281132
Volume :
473
Issue :
3
Database :
OpenAIRE
Journal :
Clinical orthopaedics and related research
Accession number :
edsair.doi.dedup.....3ac3e797d872e89ec5cae89f5de6c03e