Back to Search Start Over

Results of aortic valve repair using decellularized bovine pericardium in congenital surgery

Authors :
Antonia Schulz
Stanislav Ovroutski
Joachim Photiadis
Johanna Kretzschmar
Johannes Nordmeyer
Daria Sumbadze
Katharina R.L. Schmitt
Felix Berger
Sarah Nordmeyer
Peter Murin
Nicodème Sinzobahamvya
Friederike Danne
Oliver Miera
Mi-Young Cho
Source :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 54(6)
Publication Year :
2017

Abstract

Objectives The search for an optimal patch material for aortic valve reconstruction (AVR) is an ongoing challenge. In this study, we report our experience of AVR using decellularized bovine pericardial patch material in congenital heart surgery. Methods Data of 40 consecutive patients who underwent AVR using the CardioCel® patch (Admedus Regen Pty Ltd, Perth, WA, Australia) between February 2014 and August 2016 were retrospectively reviewed. The median age of the patients at operation was 9 (2-34) years, and 18 patients were younger than 7 years. Twenty-six patients initially presented with aortic valve insufficiency (AI) and 14 with stenosis. Clinical and echocardiographic data were available until August 2017 for a median postoperative follow-up (FU) of 22 (6-42) months. Results Nine of 40 (23%) patients experienced an event during FU (death: n = 1, 2.5%; reoperation: n = 8, 20%). Overall, the probability of freedom from reoperation or death was 97 ± 3%, 76 ± 9% and 57 ± 12% at 12, 24 and 36 months of FU, respectively. Reason for reoperation was stenosis in 3 (37.5%) patients, insufficiency in 4 (50%) patients and 1 (12.5%) patient was diagnosed with aortic valve endocarditis. Of the remaining 31 patients, 2 patients are scheduled for reoperation (aortic valve stenosis: n = 1 and AI: n = 1) and 9 patients exhibit worsening of aortic valve function with moderate AI. Freedom from developing combined end point [death/reoperation/moderate degree of aortic valve dysfunction (aortic valve stenosis, AI)] after AVR was 92 ± 5%, 55 ± 9% and 28 ± 9% at 12, 24 and 36 months, respectively. Conclusions AVR using decellularized bovine pericardial patch material in patients with congenital aortic valve disease show unsatisfactory results within the first 3 years of FU.

Details

ISSN :
1873734X
Volume :
54
Issue :
6
Database :
OpenAIRE
Journal :
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery