Effectiveness and safety of transvenous extraction of single- versus dual-coil implantable cardioverter-defibrillator leads at single-center experience
- Source :
- Medicine
- Publication Year :
- 2019
-
Abstract
- The available literature lacks data concerning direct comparison of the effectiveness and safety of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads transvenous extraction. Certainly, additional shocking coil in superior vena cava adds to the amount of metal in the vascular system. Adhesions developing around the superior vena cava coil add to the difficulty of extraction of ICD lead if lead removal is required. The aim of the study was to assess the effectiveness and safety of single- and dual-coil ICD leads transvenous extraction using mechanical systems. We performed transvenous lead extraction (TLE) of 197 ICD leads in 196 patients. There were 46 (23.3%) dual-coil leads removed from 46 (23.5%) patients. Cardiovascular implantable electronic device-related infection was an indication for TLE in 25.0% of patients. The following extracting techniques were used: manual direct traction, mechanical telescopic sheaths, controlled-rotation mechanical sheaths, and femoral approach. Complete ICD lead removal and complete procedural success in both groups were similar (99.3% in single-coil vs 97.8% in dual-coil, P = .41 and 99.3% in single-coil vs 97.8% in dual-coil, P = 0.41, respectively). We did not find significant difference between major and minor complication rates in both groups (2.0% in single-coil vs 4.3% in dual-coil, and 0.7% in single-coil vs 0.0% in dual-coil, P = .58, respectively). There was 1 death associated with the TLE procedure of single-coil lead. This study shows that extraction of dual-coil leads seems to be comparably safe and effective to extraction of single-coil leads. On the other hand, it requires longer fluoroscopy time and frequent utilization of advanced tools.
- Subjects :
- Adult
Male
medicine.medical_specialty
Vena Cava, Superior
medicine.medical_treatment
Tissue Adhesions
Single Center
03 medical and health sciences
Young Adult
0302 clinical medicine
Text mining
Superior vena cava
Risk Factors
medicine
Fluoroscopy
Humans
030212 general & internal medicine
Lead (electronics)
Device Removal
Aged
Aged, 80 and over
medicine.diagnostic_test
business.industry
Extraction (chemistry)
General Medicine
Equipment Design
Middle Aged
Implantable cardioverter-defibrillator
Surgery
Defibrillators, Implantable
Treatment Outcome
030220 oncology & carcinogenesis
Female
Erratum
Complication
business
Vascular Surgical Procedures
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Journal :
- Medicine
- Accession number :
- edsair.doi.dedup.....3a5ee4d15c0daa2cadacfc6bba73ffd6