Back to Search Start Over

Performance evaluation of partially saturated vertical-flow constructed wetland with trickling filter and chemical precipitation for domestic and winery wastewaters treatment

Authors :
S Prost-Boucle
Philippe Michel
Pascal Molle
Mathieu Gautier
Rémy Gourdon
Boram Kim
Laboratoire de Génie Civil et d'Ingénierie Environnementale (LGCIE)
Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Université de Lyon-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)
Society of design and production engineering for wastewater purification (SCIRPE)
Milieux aquatiques, écologie et pollutions (UR MALY)
Institut national de recherche en sciences et technologies pour l'environnement et l'agriculture (IRSTEA)
SCIRPE, CIFRE
Source :
Ecological Engineering, Ecological Engineering, Elsevier, 2014, 71, pp.41-47. ⟨10.1016/j.ecoleng.2014.07.045⟩
Publication Year :
2014
Publisher :
HAL CCSD, 2014.

Abstract

International audience; The use of Vertical Flow Constructed Wetlands (VFCW) is growing rapidly in Europe for domestic wastewater treatment in small communities. In order to improve denitrification and dephosphatation as compared to classical VFCW, the Azoé-NP® process has been developed. The process line consists of: a biological aerobic trickling filter as a primary treatment stage, ferric chloride (FeCl3) addition for phosphorus (P) treatment and two stages of partially saturated VFCW. A municipal wastewater treatment plant using Azoé-NP® process has been monitored during eight years through 44 campaigns of 24h time-proportional inlet-outlet sampling followed by analyses of TSS, BOD5, COD, TKN, NO3 N and TP concentrations. The results revealed good performances of the overall treatment. To better characterize the performance of each treatment step, five additional 24h monitoring campaigns were performed with samples taken from four different points along the treatment line. Results showed a good performance in dissolved carbon removal and nitrification by the trickling filter. The main part of the treatment was found to be done by filtration throughout the first filtration stage. Nitrate removal was achieved principally at the second filtration stage. Phosphorus migration through the first stage and its slight retention at the second stage was observed.

Details

Language :
English
ISSN :
09258574 and 18726992
Database :
OpenAIRE
Journal :
Ecological Engineering, Ecological Engineering, Elsevier, 2014, 71, pp.41-47. ⟨10.1016/j.ecoleng.2014.07.045⟩
Accession number :
edsair.doi.dedup.....394341555a30815f0418b2a6164870d8
Full Text :
https://doi.org/10.1016/j.ecoleng.2014.07.045⟩