Validation of the InBody BP170 oscillometric home blood pressure monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization Universal Standard
- Source :
- Blood pressure monitoring. 25(1)
- Publication Year :
- 2019
-
Abstract
- Objective To evaluate the accuracy of the InBody BP170 oscillometric upper-arm home blood pressure (BP) monitor in general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). Methods Subjects were recruited to fulfill the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. Two cuffs of the test device were used for arm circumference 22-32 (medium) and 32-42 cm (large). Results One-hundred five subjects were recruited and 88 were analyzed. For validation Criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 0.9 ± 6.9/0.5 ± 5.5 mmHg (systolic/diastolic). For Criterion 2, the SD of the averaged BP differences between the test device and reference BP per subject was 5.77/4.80 mmHg (systolic/diastolic). Conclusion The InBody BP170 oscillometric home BP monitor fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in general population and can be recommended for clinical use.
- Subjects :
- Adult
Male
medicine.medical_specialty
Validation study
Standardization
Systole
Population
030204 cardiovascular system & hematology
Assessment and Diagnosis
Medical instrumentation
03 medical and health sciences
0302 clinical medicine
Diastole
Oscillometry
Internal Medicine
Medicine
Humans
Arterial Pressure
030212 general & internal medicine
education
Societies, Medical
Aged
Advanced and Specialized Nursing
Aged, 80 and over
Measurement method
education.field_of_study
business.industry
Blood Pressure Determination
General Medicine
Middle Aged
Reference Standards
Blood Pressure Monitors
Blood pressure
Cuff
Hypertension
Physical therapy
Female
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 14735725
- Volume :
- 25
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Blood pressure monitoring
- Accession number :
- edsair.doi.dedup.....3906351b7f6d4df15cdd24efb7b0ee56