Back to Search
Start Over
Locally Targeted Delivery of a Micron-Size Radiation Therapy Source Using Temperature-Sensitive Hydrogel
- Source :
- International Journal of Radiation Oncology*Biology*Physics. 88:1142-1147
- Publication Year :
- 2014
- Publisher :
- Elsevier BV, 2014.
-
Abstract
- Purpose To propose a novel radiation therapy (RT) delivery modality: locally targeted delivery of micron-size RT sources by using temperature-sensitive hydrogel (RT-GEL) as an injectable vehicle. Methods and Materials Hydrogel is a water-like liquid at room temperature but gels at body temperature. Two US Food and Drug Administration-approved polymers were synthesized. Indium-111 (In-111) was used as the radioactive RT-GEL source. The release characteristics of In-111 from polymerized RT-GEL were evaluated. The injectability and efficacy of RT-GEL delivery to human breast tumor were tested using animal models with control datasets of RT-saline injection. As proof-of-concept studies, a total of 6 nude mice were tested by injecting 4 million tumor cells into their upper backs after a week of acclimatization. Three mice were injected with RT-GEL and 3 with RT-saline. Single-photon emission computed tomography (SPECT) and CT scans were performed on each mouse at 0, 24, and 48 h after injection. The efficacy of RT-GEL was determined by comparison with that of the control datasets by measuring kidney In-111 accumulation (mean nCi/cc), representing the distant diffusion of In-111. Results RT-GEL was successfully injected into the tumor by using a 30-gauge needle. No difficulties due to polymerization of hydrogel during injection and intratumoral pressure were observed during RT-GEL injection. No back flow occurred for either RT-GEL or RT-saline. The residual tumor activities of In-111 were 49% at 24 h (44% at 48 h, respectively) for RT-GEL and 29% (22%, respectively) for RT-saline. Fused SPECT-CT images of RT-saline showed considerable kidney accumulation of In-111 (2886%, 261%, and 262% of RT-GEL at 0, 24, and 48 h, respectively). Conclusions RT-GEL was successfully injected and showed much higher residual tumor activity: 170% (200%, respectively), than that of RT-saline at 24 h (48 h, respectively) after injection with a minimal accumulation of In-111 to the kidneys. Preliminary data of RT-GEL as a delivery modality of a radiation source to a local tumor are promising.
- Subjects :
- Cancer Research
Time Factors
Polymers
medicine.medical_treatment
Tumor cells
Single-photon emission computed tomography
Article
Injections
Mice
Cell Line, Tumor
Pressure
Animals
Humans
Medicine
Radiology, Nuclear Medicine and imaging
Tomography, Emission-Computed, Single-Photon
Kidney
Radiation
Micron size
Radiotherapy
medicine.diagnostic_test
business.industry
Indium Radioisotopes
Temperature
Mammary Neoplasms, Experimental
Hydrogels
Xenograft Model Antitumor Assays
Radiation therapy
medicine.anatomical_structure
Oncology
Models, Animal
Female
Temperature sensitive
Tomography, X-Ray Computed
business
Nuclear medicine
Human breast
Neoplasm Transplantation
Emission computed tomography
Subjects
Details
- ISSN :
- 03603016
- Volume :
- 88
- Database :
- OpenAIRE
- Journal :
- International Journal of Radiation Oncology*Biology*Physics
- Accession number :
- edsair.doi.dedup.....38f91d8d594800a4885e3a2add30e373
- Full Text :
- https://doi.org/10.1016/j.ijrobp.2013.12.025