Back to Search
Start Over
A within‐coil optical prospective motion‐correction system for brain imaging at 7T
- Source :
- Magn Reson Med
- Publication Year :
- 2020
- Publisher :
- Wiley, 2020.
-
Abstract
- PURPOSE: Motion artifact limits the clinical translation of high-field MR. We present an optical prospective motion correction system for 7 Tesla MRI using a custom-built, within-coil camera to track an optical marker mounted on a subject. METHODS: The camera was constructed to fit between the transmit-receive coils with direct line of sight to a forehead-mounted marker, improving upon prior mouthpiece work at 7 Tesla MRI. We validated the system by acquiring a 3D-IR-FSPGR on a phantom with deliberate motion applied. The same 3D-IR-FSPGR and a 2D gradient echo were then acquired on 7 volunteers, with/without deliberate motion and with/without motion correction. Three neuroradiologists blindly assessed image quality. In 1 subject, an ultrahigh-resolution 2D gradient echo with 4 averages was acquired with motion correction. Four single-average acquisitions were then acquired serially, with the subject allowed to move between acquisitions. A fifth single-average 2D gradient echo was acquired following subject removal and reentry. RESULTS: In both the phantom and human subjects, deliberate and involuntary motion were well corrected. Despite marked levels of motion, high-quality images were produced without spurious artifacts. The quantitative ratings confirmed significant improvements in image quality in the absence and presence of deliberate motion across both acquisitions (P < .001). The system enabled ultrahigh-resolution visualization of the hippocampus during a long scan and robust alignment of serially acquired scans with interspersed movement. CONCLUSION: We demonstrate the use of a within-coil camera to perform optical prospective motion correction and ultrahigh-resolution imaging at 7 Tesla MRI. The setup does not require a mouthpiece, which could improve accessibility of motion correction during 7 Tesla MRI exams.
- Subjects :
- Image quality
Computer science
Neuroimaging
Translation (geometry)
Article
Imaging phantom
Motion (physics)
030218 nuclear medicine & medical imaging
Motion
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Radiology, Nuclear Medicine and imaging
Computer vision
Prospective Studies
Mouthpiece
Artifact (error)
medicine.diagnostic_test
business.industry
Brain
Magnetic resonance imaging
Magnetic Resonance Imaging
Artificial intelligence
Artifacts
business
030217 neurology & neurosurgery
Subjects
Details
- ISSN :
- 15222594 and 07403194
- Volume :
- 84
- Database :
- OpenAIRE
- Journal :
- Magnetic Resonance in Medicine
- Accession number :
- edsair.doi.dedup.....38e77ae8f9d98b68bca341339a298b88
- Full Text :
- https://doi.org/10.1002/mrm.28211