Back to Search Start Over

OCT and ERG Techniques in High-Throughput Phenotyping of Mouse Vision

Authors :
Jiri Lindovsky
Marcela Palkova
Viktoriia Symkina
Miles Joseph Raishbrook
Jan Prochazka
Radislav Sedlacek
Source :
Genes, Volume 14, Issue 2, Pages: 294
Publication Year :
2023
Publisher :
MDPI AG, 2023.

Abstract

The purpose of the study is to demonstrate coherent optical tomography and electroretinography techniques adopted from the human clinical practice to assess the morphology and function of the mouse retina in a high-throughput phenotyping environment. We present the normal range of wild-type C57Bl/6NCrl retinal parameters in six age groups between 10 and 100 weeks as well as examples of mild and severe pathologies resulting from knocking out a single protein-coding gene. We also show example data obtained by more detailed analysis or additional methods useful in eye research, for example, the angiography of a superficial and deep vascular complex. We discuss the feasibility of these techniques in conditions demanding a high-throughput approach such as the systemic phenotyping carried out by the International Mouse Phenotyping Consortium.

Details

ISSN :
20734425
Volume :
14
Database :
OpenAIRE
Journal :
Genes
Accession number :
edsair.doi.dedup.....36fb3c9ac08259b56899db5c1c75d40e
Full Text :
https://doi.org/10.3390/genes14020294