Pacemakers implantation and radiofrequency catheter ablation procedures during medical missions in Morocco: an 8-year experience

Authors :
Naima Zarqane
Sok-Sithikun Bun
Amale Tazi-Mezalek
Nadir Saoudi
Abdelhamid Moustaghfir
K. Yaici
Decebal Gabriel Latcu
Abdelkarim Errahmouni
Source :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 18(7)
Publication Year :
2015

Abstract

Aims Radiofrequency catheter ablation (RFCA) for arrhythmias in the context of short-term medical missions (MM) in a developing country has not been reported so far. We describe here our experience with RFCA and pacemaker implantation in Morocco with a fully portable electrophysiological (EP) system under the auspice of the Monaco–Morocco Cardiology Association. Methods and results Since November 2007, two to three MM (mean duration 4 days including transportation) per year were conducted (including two physicians and one nurse from Monaco) and were alternately located in Marrakech, Fes, Agadir, Casablanca, Rabat, Essaouira, and Oujda. All patients’ files were sent by local teams and/or referring Moroccan cardiologists before MM. Each case was discussed with the Monaco EP team before the MM. Pacemakers and leads were donated by companies (Sorin Group, Medtronic, Saint-Jude Medical). The EP system (EP Tracer, CardioTek) as well as diagnostic/ablation catheters were brought for RFCA procedures. After the procedures, follow-up was performed by local teams. Procedures took place in gynaecological or orthopaedic operating room, or, when available, in the interventional cardiology cathlab. Thirty-one RFCA were performed during 11 MM (atrioventricular node re-entrant tachycardia = 12; atrioventricular re-entrant tachycardia/Mahaim fibre = 15; typical atrial flutter = 3; ventricular ectopy = 1). Acute success was 93.5% for RFCA. Two major RFCA-related complications occurred (air embolism and complete atrioventricular block). No complication was related to pacemaker implantations ( n = 44; mean 4 pacemakers per mission). Conclusion Radiofrequency catheter ablation for arrhythmias in developing countries is technically challenging but feasible, despite technical and cultural difficulties.

Details

ISSN :
15322092
Volume :
18
Issue :
7
Database :
OpenAIRE
Journal :
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
Accession number :
edsair.doi.dedup.....36faf2316b8526da0fbebf4dcb6c2891