Back to Search
Start Over
The point of epiphyseal penetration affects rotational stability of screw fixation in slipped capital femoral epiphysis: A biomechanical study
- Source :
- Journal of Orthopaedic Research. 38:2634-2639
- Publication Year :
- 2020
- Publisher :
- Wiley, 2020.
-
Abstract
- The epiphyseal tubercle, a posterosuperior projection of the epiphysis into the metaphysis, serves as the axis of rotation in slipped capital femoral epiphysis (SCFE) and a source of physeal stability. We hypothesized that in a biomechanical model of single screw fixation of stable SCFE, a screw passing through the epiphyseal tubercle (the axis of rotation) would confer less rotational stability than a centrally placed screw. Three femurs were selected from a sample population of 8- to 15-year-old healthy hips to represent three stages of maturation: a "young" femur with a prominent epiphyseal tubercle and decreased epiphyseal cupping around the metaphysis, a "median" femur with a subsiding tubercle, and a "mature" femur with a subsided epiphyseal tubercle and increased peripheral epiphyseal cupping. Specimens were three-dimensional printed with one of two screw trajectories: passing centrally in the epiphysis or directly through the epiphyseal tubercle. Resistance to rotational displacement was measured through stiffness and maximum torque over 30° degrees of displacement. In the "young" model, epiphyseal tubercle screw position conferred less rotational stiffness and required less maximum torque during rotational displacement when compared to a centrally placed screw (P < .001). In the "median" and "mature" models where the tubercle has subsided and is replaced by peripheral epiphyseal cupping, screw position through the tubercle was associated with equal or greater rotational stiffness and maximum torque during displacement as a centrally placed screw.
- Subjects :
- Adolescent
Tubercle
Bone Screws
0206 medical engineering
Slipped Capital Femoral Epiphyses
02 engineering and technology
Metaphysis
Screw fixation
03 medical and health sciences
0302 clinical medicine
medicine
Humans
Orthopedic Procedures
Orthopedics and Sports Medicine
Femur
Displacement (orthopedic surgery)
Child
030203 arthritis & rheumatology
business.industry
Angular displacement
Anatomy
medicine.disease
020601 biomedical engineering
Biomechanical Phenomena
medicine.anatomical_structure
Torque
Epiphysis
Printing, Three-Dimensional
business
Slipped capital femoral epiphysis
Epiphyses
Subjects
Details
- ISSN :
- 1554527X and 07360266
- Volume :
- 38
- Database :
- OpenAIRE
- Journal :
- Journal of Orthopaedic Research
- Accession number :
- edsair.doi.dedup.....353cd9c1e39a6e86046afe3dec7eaa99
- Full Text :
- https://doi.org/10.1002/jor.24747