粘性・粘弾性ダンパーを有する高層建物の風応答特性に関する風洞実験
- Source :
- 日本建築学会構造系論文集. :95-102
- Publication Year :
- 2007
- Publisher :
- 一般社団法人日本建築学会, 2007.
-
Abstract
- This paper discusses the wind tunnel tests for a tall building model having either viscous or visco-elastic damper under the turbulent boundary layer flow. The wind tunnel tests are carried out either the across- or along-wind direction for the viscous and the visco-elastic damper systems, respectively. This wind test set-up includes a special measurement system to obtain the damper hysteetic loop, then the response property of damper and system are discussed by the referring to the obtained loop. In case of the severe wind speed, the response of visco-elastic system is smaller than the viscous system because the stiffness of visco-elastic damper contributes to the stiffness of system.
- Subjects :
- Property (philosophy)
business.industry
passive control, viscous damper, visco-elastic damper, frequency sensitivity, wind tunnel tests, turbulent boundary layer flow
Building and Construction
Structural engineering
Viscoelasticity
Damper
Physics::Fluid Dynamics
Architecture
Physics::Space Physics
Geotechnical engineering
business
パッシブ制振, 粘性ダンパー, 粘弾性ダンパー, 振動数依存, 風洞実験, 境界層乱流
Geology