Tibial fixation of anterior cruciate ligament allograft tendons: comparison of 1-, 2-, and 4-stranded constructs
- Source :
- The American journal of sports medicine. 37(8)
- Publication Year :
- 2009
-
Abstract
- BackgroundIn sum, 1-, 2-, and 4-stranded allografts are used for soft tissue anterior cruciate ligament reconstruction; however, the fixation properties of fixation devices are not well assessed.HypothesisThere are no differences in the biomechanical characteristics of 1 (Achilles)-, 2 (posterior tibialis)-, and 4 (semitendinosus)-stranded allograft tibial fixation.Study DesignControlled laboratory study.MethodsSixty-three fresh-frozen porcine tibiae were used to evaluate the fixation of 1-, 2-, and 4-stranded human tendon allografts (Achilles, posterior tibialis, and semitendinosus) with 3 fixation devices (Delta, Intrafix, and Calaxo screws). With use of a materials testing system, each graft was subjected to 500 cycles of loading (50-250 N, 0.75 mm/sec) to determine displacement and cyclic stiffness, followed by a monotonic failure test (20 mm/min) to determine maximum load and pullout stiffness.ResultsFor each graft type, there were no significant biomechanical differences between fixation devices. However, the 1-stranded graft (Achilles) construct demonstrated significantly higher mean displacement (3.17 ± 1.62 mm), lower cyclical stiffness (156 ± 25 N/mm), lower load to failure (479 ± 87 N), and lower pullout stiffness (140 ± 28 N/mm). In comparison with the 2-stranded graft (posterior tibialis), the 4-stranded graft (semitendinosus) exhibited lower displacement (0.86 ± 0.44 to 1.12 ± 0.51 mm) and higher ultimate failure load (832 ± 255 to 656 ± 168 N). Numerous differences in fixation properties were noted when comparing a device to each of the 3 grafts.ConclusionThe 1-stranded allograft demonstrated inferior biomechanical tibial fixation properties when compared with 2 (posterior tibialis)- and 4 (semitendinosus)-stranded allograft constructs for all fixation devices tested.Clinical RelevanceThis study demonstrated that not all tibial fixation devices are designed to adequately accommodate different types of anterior cruciate ligament allografts. Biomechanical evidence suggests that caution is warranted when using an Achilles allograft fixated solely with an interference device.
- Subjects :
- Anterior cruciate ligament reconstruction
Tibia
business.industry
Swine
Anterior cruciate ligament
medicine.medical_treatment
Bone Screws
Soft tissue
Physical Therapy, Sports Therapy and Rehabilitation
Anatomy
Tendon
Biomechanical Phenomena
Transplantation
Fixation (surgical)
medicine.anatomical_structure
Cadaver
medicine
Animals
Transplantation, Homologous
Orthopedics and Sports Medicine
Orthopedic Procedures
Anterior Cruciate Ligament
business
Subjects
Details
- ISSN :
- 15523365
- Volume :
- 37
- Issue :
- 8
- Database :
- OpenAIRE
- Journal :
- The American journal of sports medicine
- Accession number :
- edsair.doi.dedup.....350b7381cf069e636613a23d7224400c