Back to Search Start Over

Comparison of 3 T and 7 T ASL techniques for concurrent functional perfusion and BOLD studies

Authors :
Anna Gardumi
Roy A.M. Haast
Benedikt A. Poser
Dimo Ivanov
Josef Pfeuffer
Kâmil Uludağ
RS: FPN CN 5
MRI
RS: FSE MaCSBio
RS: FPN MaCSBio
Source :
Neuroimage, 156, 363-376. Elsevier Science
Publication Year :
2017
Publisher :
Elsevier BV, 2017.

Abstract

Arterial spin labeling (ASL) is the primary non-invasive MRI approach to measure baseline cerebral blood flow (CBF) in healthy subjects and patients. ASL also allows concurrent functional BOLD signal and CBF measurements, but the latter typically suffer from low contrast-to-noise (CNR) ratio. Ultra-high-field imaging significantly boosts BOLD signal CNR. However, it is contested whether also CBF CNR benefits from increasing magnetic field strength, especially given that technical challenges related to field inhomogeneities and power deposition constraints exist. Recently, we presented an optimized PASL technique that utilizes tr-FOCI inversion pulses and dielectric pads to overcome the temporal resolution limitations of previous 7T ASL implementations (Ivanov et al., in press; 2017). The primary goal of this study was to compare its performance to that of 3T ASL approaches - both pulsed ASL (PASL) and pseudo-continuous (pCASL) - concerning functional studies using simultaneous CBF and BOLD signal acquisition. To this aim, we investigated a wide range of parameters that can influence CBF and BOLD signal sensitivities: spatial resolution, labeling scheme, parallel imaging and echo time. We found that 7T ASL is superior in terms of CBF and BOLD temporal signal-to-noise ratio (SNR) and activation volume compared to all 3T ASL variants, in particular at high spatial resolution. Our results show that the advantages of 7T for ASL stem from increased image SNR, especially when parallel imaging is used. The gray matter baseline CBF was in good agreement for all 3T ASL variants, but a significantly lower value was obtained at 7T. The labeling scheme utilized was also found to significantly influence the measured perfusion territories CBF. In conclusion, a single-echo accelerated 7T PASL is recommended for high spatial and temporal resolution CBF and BOLD imaging, while a 3T dual-echo pCASL approach without parallel imaging may be preferred for low (i.e., 3mm isotropic and lower) resolution functional perfusion and BOLD applications.

Details

ISSN :
10538119
Volume :
156
Database :
OpenAIRE
Journal :
NeuroImage
Accession number :
edsair.doi.dedup.....33583037215623319740f6a01b83be83
Full Text :
https://doi.org/10.1016/j.neuroimage.2017.05.038