Back to Search Start Over

Performance evaluation of the highly sensitive histidine-rich protein 2 rapid test for plasmodium falciparum malaria in North-West Tanzania

Authors :
Eric Lyimo
Paul Kazyoba
Donald Miyaye
John Changalucha
Lucas E. Matemba
Alphaxard Manjurano
Justin J. Omolo
Julius J. Massaga
Coleman Kishamawe
Source :
Malaria Journal, Malaria Journal, Vol 20, Iss 1, Pp 1-9 (2021)
Publication Year :
2020

Abstract

Background Precise detection of Plasmodium infections in community surveys is essential for effective malaria control. Microscopy and rapid diagnostic tests (RDTs) are the major techniques used to identify malaria infections in the field-based surveys. Although microscopy is still considered as the gold standard, RDTs are increasingly becoming versatile due to their rapid and adequate performance characteristics. Methods A malaria prevalence cross-sectional survey was carried out in north-western Tanzania in 2016, aimed at appraising the performance of high sensitivity Plasmodium falciparum (HSPf) tests compared to SD Bioline Pf and microscopy in detecting P. falciparum infections. A total of 397 individuals aged five years and above were tested for P. falciparum infections. The sensitivity, specificity, positive, and negative predictive values (PPV and NPV) of microscopy, Pf RDT and HSPf RDT was determined using PCR as the gold standard method. Results The prevalence of P. falciparum infections determined by microscopy, SD Bioline Pf, HSPf and PCR was 21.9, 27.7, 33.3 and 43.2%, respectively. The new HSPf RDT had significantly higher sensitivity (98.2%) and specificity (91.6%) compared to the routinely used SD Bioline Pf RDT(P Conclusions HSPf RDT had better performance when compared to both microscopy and the currently used malaria RDTs. The false negativity could be associated with the low parasite density of the samples. False positivity may be related to the limitations of the expertise of microscopists or persistent antigenicity from previous infections in the case of RDTs. Nevertheless, HS PfRDT performed better compared to routinely used Pf RDT, and microscopy in detecting malaria infections. Therefore, HS Pf RDT presents the best alternative to the existing commercial/regularly available RDTs due to its sensitivity and specificity, and reliability in diagnosing malaria infections.

Details

ISSN :
14752875
Volume :
20
Issue :
1
Database :
OpenAIRE
Journal :
Malaria journal
Accession number :
edsair.doi.dedup.....332f7d0821e484f57386fa1ec7b2a6e7