Assessment of intracochlear electrode position and correlation with behavioural thresholds in CII and 90K cochlear implants
- Source :
- Acta Oto-Laryngologica. 128:291-296
- Publication Year :
- 2008
- Publisher :
- Informa UK Limited, 2008.
-
Abstract
- The image quality of 64-MDCT provided excellent definition of the fine osseous structures and individual electrode contacts. Evaluation of electrode distances revealed a more focused stimulation for the Helix contacts, with better optimization of pulse width and frequency of stimulation.A multi-slice CT scan was performed postoperatively to evaluate electrode distance from the modiolus and variability of fitting parameters (M level) for two different types of cochlear implant electrode carriers, CII and 90K implants with 1J and Helix electrode carriers.The electrode's position in different cochlear implant (CI) electrodes, Advanced Bionics 90K 1J and Helix, was assessed postoperatively in 20 adult patients by means of a 64-MDCT scanner. Axial, coronal, and oblique 0.3 mm multiplanar reconstructions (MPRs) were obtained and datasets were analyzed to assess the intracochlear position and distance from the surface of the electrodes to the bony edge of the modiolus. Patients' fitting characteristics were gathered at the time the CT was performed and correlated to intracochlear measurements.Determination of contact distances confirmed smaller average values for the Helix at the apex and medial segments. Helix electrodes were closer to the modiolus in all segments. Likewise, M level determination showed lower values for the Helix carrier, confirming a more focused stimulation and better optimization of pulse width and frequency of stimulation.
- Subjects :
- Adult
Male
medicine.medical_specialty
Materials science
Image quality
medicine.medical_treatment
Computed tomography
Audiology
Prosthesis Design
Correlation
Prosthesis fitting
Prosthesis Fitting
Cochlear implant
Image Processing, Computer-Assisted
Electrode array
medicine
Humans
Prosthesis design
Aged
medicine.diagnostic_test
Auditory Threshold
General Medicine
Middle Aged
Cochlear Implantation
Cochlea
Electrodes, Implanted
Cochlear Implants
Otorhinolaryngology
Electrode
Female
Spiral Ganglion
Tomography, Spiral Computed
behavioral threshold
cochlear implant
computed tomography
electrode array
Subjects
Details
- ISSN :
- 16512251 and 00016489
- Volume :
- 128
- Database :
- OpenAIRE
- Journal :
- Acta Oto-Laryngologica
- Accession number :
- edsair.doi.dedup.....32d39e9adf475e810ead8f413e6bdedb