Feasibility study of near-infrared fluorescence tomography using a positron emission tomograph equipped with depth-of-interaction PET detectors
- Source :
- Radiological Physics and Technology. 2:189-197
- Publication Year :
- 2009
- Publisher :
- Springer Science and Business Media LLC, 2009.
-
Abstract
- We are currently developing an imaging system that combines simultaneous positron emission tomography (PET) with near-infrared (NIR) optical tomography, thus supporting two different types of molecular imaging. For this system, we are considering whether to use depth of interaction (DOI) PET detectors as simultaneous detectors of gamma rays and NIR light by changing the original upper reflectors to dichroic mirrors. The DOI-PET detector has very low spatial resolution for NIR light compared to the charge-coupled device cameras that are normally used. However, it is possible to reconstruct images of comparable value from the data acquired by low-resolution devices because the light is scattered by biological tissues and high-resolution devices are not necessarily effective at improving image quality. In this study, we demonstrate the feasibility of 3D NIR fluorescence tomography imaging by employing DOI-PET detectors in computer simulations. In the simulations, we used a 40 mm x 40 mm x 40 mm cubic phantom, a square detector geometry, and an optical diffusion equation to approximate the light propagation. We then evaluated imaging systems for 3D fluorescence tomography with different detector resolutions and excitation light arrangements using singular-value analysis and imaging simulation. We confirmed that the reconstructed images from low-resolution detectors (8 x 8 pixels for an area of 40 mm x 40 mm) are the same as those from high-resolution detectors (16 x 16 pixels for the same area).
- Subjects :
- Light
Infrared Rays
Physics::Instrumentation and Detectors
Physics::Medical Physics
Physical Therapy, Sports Therapy and Rehabilitation
Dichroic glass
Imaging phantom
Imaging, Three-Dimensional
Optics
medicine
Radiology, Nuclear Medicine and imaging
Optical tomography
Tomography
Image resolution
Physics
Radiation
Pixel
medicine.diagnostic_test
business.industry
Detector
General Medicine
Models, Theoretical
Systems Integration
Positron emission tomography
Positron-Emission Tomography
Feasibility Studies
business
Subjects
Details
- ISSN :
- 18650341 and 18650333
- Volume :
- 2
- Database :
- OpenAIRE
- Journal :
- Radiological Physics and Technology
- Accession number :
- edsair.doi.dedup.....32c2670e4e02dfdc06b4ca7bbad284c0