Back to Search
Start Over
Tricuspid leaflet kinematics after annular size reduction in ovine functional tricuspid regurgitation
- Source :
- The Journal of Thoracic and Cardiovascular Surgery. 164:e353-e366
- Publication Year :
- 2022
- Publisher :
- Elsevier BV, 2022.
-
Abstract
- Objective Tricuspid annular size reduction with annuloplasty rings represents the foundation of surgical repair of functional tricuspid regurgitation. However, the precise effect of annular size reduction on leaflet motion and geometry remains unknown. Methods Ten sheep underwent surgical implantation of a pacemaker with an epicardial lead and were paced 200-240 beats/min to achieve biventricular dysfunction and functional tricuspid regurgitation. Subsequently, sonomicrometry crystals were implanted on the right ventricle, the tricuspid annulus, and on the belly of anterior, posterior, and septal tricuspid leaflets. Double-layer polypropylene suture was placed around the tricuspid annulus and externalized to a tourniquet. Simultaneous echocardiographic, hemodynamic, and sonomicrometry data were acquired with functional tricuspid regurgitation and during 5 consecutive annular reduction steps. Annular area, tenting height, and volume, together with each leaflet strain, radial length, and angles, were calculated from crystal coordinates. Results Rapid pacing reduced both left ventricle and right ventricle function and induced functional tricuspid regurgitation (0-3+) in all animals (from 0 ± 0 to 2.4 ± 0.7, P = .002), whereas tricuspid annulus diameter increased from 2.6 ± 0.3 cm to 3.3 ± 0.3 cm (P = .001). Tricuspid annular size reduction 1 to 5 resulted in 16% ± 7%, 37% ± 11%, 55% ± 11%, 66% ± 10%, and 76% ± 8% tricuspid annulus area reduction, respectively, and successively decreased tricuspid regurgitation. Tricuspid annular size reduction 2 to 5 induced anterior and posterior leaflet restricted motion and lower diastolic motion velocities. Tricuspid annular size reduction 5 perturbed septal leaflet range of motion but preserved its angle velocities. Tricuspid annular size reduction 3-5 generated compressive strains in all leaflets. Conclusions Tricuspid annular area reduction of 55% perturbed anterior and posterior leaflet motion while maintaining normal septal leaflet movement. More extreme reduction triggered profound changes in anterior and posterior leaflet motion, suggesting that aggressive undersizing impairs leaflet kinematics.
- Subjects :
- Pulmonary and Respiratory Medicine
congenital, hereditary, and neonatal diseases and abnormalities
medicine.medical_specialty
medicine.medical_treatment
Diastole
Regurgitation (circulation)
030204 cardiovascular system & hematology
03 medical and health sciences
0302 clinical medicine
Internal medicine
medicine
Animals
cardiovascular diseases
Reduction (orthopedic surgery)
Mitral regurgitation
Sheep
Tricuspid valve
business.industry
Hemodynamics
Tricuspid Valve Insufficiency
Biomechanical Phenomena
medicine.anatomical_structure
Sonomicrometry
030228 respiratory system
Echocardiography
Ventricle
cardiovascular system
Cardiology
Surgery
Tricuspid Valve
Cardiology and Cardiovascular Medicine
Range of motion
business
Subjects
Details
- ISSN :
- 00225223
- Volume :
- 164
- Database :
- OpenAIRE
- Journal :
- The Journal of Thoracic and Cardiovascular Surgery
- Accession number :
- edsair.doi.dedup.....30a0ba8b74b5514583b48f590d79fb3c