Back to Search
Start Over
Early shape change behaviour of an uncemented contemporary hip cup: A cadaveric experiment replicating host bone behaviour through temperature control
- Source :
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 232:843-849
- Publication Year :
- 2018
- Publisher :
- SAGE Publications, 2018.
-
Abstract
- Modular uncemented acetabular components are in common use. Fixation is dependent upon press-fit but the forces necessary to achieve initial stability of the construct at implantation may deform the shell and prevent optimal seating of the polyethylene liner insert. Previous work using single-time point measurements in uncontrolled ambient temperature poorly replicates the native state. A controlled study was performed to observe the time-dependent behaviour of an uncemented acetabular shell in the early phase after implantation into the human acetabulum at near physiological temperature. Using a previously validated cadaveric hip model at controlled near physiological temperature with standardised surgical technique, immediate and delayed shell geometry was determined. Eight custom made 3-mm-thick titanium alloy (TiAl6V4) shells were implanted into four cadavers (eight hips). Time-dependent shell deformation was determined using the previously validated ATOS Triple Scan III (ATOS) optical measurement system. The pattern of change in the shape of the surgically implanted shell was measured at three time points after insertion. We found a consistent pattern for quantitative and directional deformation of the shells. In addition, there was consistency for relaxation of the deformation with time. Immediate mean change in shell radius was 104 µm (standard deviation 32, range 67–153) relaxing to mean 96 µm (standard deviation 32, range 63–150) after 10 min and mean 92 µm (standard deviation 28, range 66–138) after 20 min. The clinical significance of this work is the finding of a time-dependent early deformation of acetabular titanium shells on insertion adjusted for near physiological temperature-controlled host bone.
- Subjects :
- Orthodontics
030222 orthopedics
Materials science
Shape change
Temperature control
Mechanical Engineering
0206 medical engineering
Temperature
Acetabulum
02 engineering and technology
General Medicine
Initial stability
020601 biomedical engineering
Biomechanical Phenomena
03 medical and health sciences
Fixation (surgical)
0302 clinical medicine
Materials Testing
Cadaver
Humans
Host bone
Hip Prosthesis
Tomography, X-Ray Computed
Cadaveric spasm
Mechanical Phenomena
Subjects
Details
- ISSN :
- 20413033 and 09544119
- Volume :
- 232
- Database :
- OpenAIRE
- Journal :
- Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Accession number :
- edsair.doi.dedup.....3074a444e084d6c61381ffb8dc5325af
- Full Text :
- https://doi.org/10.1177/0954411918790776