Back to Search Start Over

Locking Compression Plate with Minimally Invasive Plate Osteosynthesis in diaphyseal and distal tibial fracture: A retrospective study of 32 patients

Authors :
Daniel Rikli
E. Hasenboehler
Reto Babst
Source :
Injury. 38:365-370
Publication Year :
2007
Publisher :
Elsevier BV, 2007.

Abstract

Summary With the introduction of Locking Compression Plates (LCP), Minimally Invasive Plate Osteosynthesis (MIPO) has become widely used. The plates act as internal fixators in a bridging manner, thus resulting in secondary bone healing. We retrospectively evaluated the healing pattern and the clinical evolution of diaphyseal and distal tibial shaft fractures over two and a half years in 32 patients (6 females, 26 males). Fractures were classified according to AO classification and included all 42A-C, 43A-B and 43C1-2 types. For open fractures, Gustillo Anderson classification was used. Plates consisted of the 4.5 mm LCP and 3.5 mm LCP-Pilon form plate. Clinical and radiological assessment was performed at 6 weeks, and at 3, 6, 9, and 12 months. Two patients were lost to follow-up. Fracture healing was defined as callus bridging of one cortex, seen on both lateral and posterior–anterior X-ray, and full, painless weight bearing. Ten patients at 3 months, 23 at 6 months, and 27 at 9 months met the criteria for a healed fracture. Plate bending was observed in one patient and called for re-operation at 5 months. Two patients required re-operation at 13 months secondary to pseudoarthrosis. Though MIPO seems more advantageous for soft tissue and bone biology, prolonged healing was observed in simple fracture patterns when a bridging plate technique was used.

Details

ISSN :
00201383
Volume :
38
Database :
OpenAIRE
Journal :
Injury
Accession number :
edsair.doi.dedup.....301b48b7db3ec8cbb4497b629af727e8
Full Text :
https://doi.org/10.1016/j.injury.2006.10.024