Back to Search
Start Over
The effect of glass fiber posts and ribbons on the fracture strength of teeth with flared root canals restored using composite resin post and cores
- Source :
- Journal of prosthodontic research. 62(1)
- Publication Year :
- 2016
-
Abstract
- This study evaluated the fracture strength and mode of failure of structurally compromised teeth with flared root canals restored using composite resin with four different systems.Sixty endodontically treated bovine teeth were uniformly shaped to simulate human mandibular premolars with flared root canals. The roots were divided into four groups of 15 specimens each based on the type of restoration: composite resin core only (control), glass fiber post, cylindroid glass fiber ribbons, and glass fiber post and ribbons. All specimens were loaded until fracture occurred using a universal testing machine. Average fracture loads were compared with a one-way ANOVA and Tukey HSD test (α=.05). The modes of failure were observed and the Fisher exact test and Bonferroni correction were used for statistical analysis.The fiber post and ribbon group (1035.70N) and the fiber ribbon group (881.77N) showed significantly higher fracture strength than the controls (567.97N) (p.05). The fiber post and ribbon group also showed significantly higher fracture strength than the fiber post group (769.40N). Almost all specimens showed unrestorable root fractures (p.008). The control group had a significantly higher ratio of core sectional fractures (p.017).Cylindroid glass fiber ribbons significantly increased the fracture strength of the composite resin post and cores in the case of the dentin within the thin root canal wall. Based on the results, this study recommends the combined use of glass fiber post and ribbons.
- Subjects :
- Dental Stress Analysis
Materials science
Root canal
0206 medical engineering
Composite number
Glass fiber
Polyurethanes
Acrylic Resins
02 engineering and technology
Composite Resins
03 medical and health sciences
Tooth Fractures
0302 clinical medicine
stomatognathic system
Flexural strength
Materials Testing
medicine
Dentin
Dentistry (miscellaneous)
Fiber
Dental Restoration Failure
Composite material
Universal testing machine
030206 dentistry
020601 biomedical engineering
Core (optical fiber)
medicine.anatomical_structure
sense organs
Glass
Stress, Mechanical
Oral Surgery
Dental Pulp Cavity
Dental Restoration Repair
Post and Core Technique
Subjects
Details
- ISSN :
- 22124632
- Volume :
- 62
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- Journal of prosthodontic research
- Accession number :
- edsair.doi.dedup.....2fd801aa3eb3072e99b6ade80663d34a