Back to Search Start Over

Repeatability and reproducibility of deep-learning-based liver volume and Couinaud segment volume measurement tool

Authors :
Anthony Puddu
Hildo J. Lamb
Angela Barone
Ged Ridgway
Rajarshi Banerjee
Matt Kelly
Amirkasra Mojtahed
Carlos Ferreira
John Connell
Zobair Arya
J. Michael Brady
Luis Núñez
Mariana Marieiro
Rowan C. Nicholls
Alessandro Fichera
Felipe Caseiro-Alves
Source :
Abdominal Radiology, 47, 143-151. SPRINGER, Abdominal Radiology, Abdominal Radiology (New York)
Publication Year :
2021

Abstract

Purpose Volumetric and health assessment of the liver is crucial to avoid poor post-operative outcomes following liver resection surgery. No current methods allow for concurrent and accurate measurement of both Couinaud segmental volumes for future liver remnant estimation and liver health using non-invasive imaging. In this study, we demonstrate the accuracy and precision of segmental volume measurements using new medical software, Hepatica™. Methods MRI scans from 48 volunteers from three previous studies were used in this analysis. Measurements obtained from Hepatica™ were compared with OsiriX. Time required per case with each software was also compared. The performance of technicians and experienced radiologists as well as the repeatability and reproducibility were compared using Bland–Altman plots and limits of agreement. Results High levels of agreement and lower inter-operator variability for liver volume measurements were shown between Hepatica™ and existing methods for liver volumetry (mean Dice score 0.947 ± 0.010). A high consistency between technicians and experienced radiologists using the device for volumetry was shown (± 3.5% of total liver volume) as well as low inter-observer and intra-observer variability. Tight limits of agreement were shown between repeated Couinaud segment volume (+ 3.4% of whole liver), segmental liver fibroinflammation and segmental liver fat measurements in the same participant on the same scanner and between different scanners. An underestimation of whole-liver volume was observed between three non-reference scanners. Conclusion Hepatica™ produces accurate and precise whole-liver and Couinaud segment volume and liver tissue characteristic measurements. Measurements are consistent between trained technicians and experienced radiologists. Graphic abstract

Details

Language :
English
Database :
OpenAIRE
Journal :
Abdominal Radiology, 47, 143-151. SPRINGER, Abdominal Radiology, Abdominal Radiology (New York)
Accession number :
edsair.doi.dedup.....2fc0b645d6e16c7d6b75f065efeb70fa