Abstract
- The reliability of low-voltage inverter-fed motors is highly dependent on the inception of partial discharges. The effect of impulsive waveform parameters must be investigated to predict the repetitive partial discharge inception voltage (RPDIV) and define test procedures that can indicate properly the behavior in service of the insulation system. This paper focuses on the RPDIV of magnet wires using twisted pairs subjected to repetitive unipolar impulsive voltage waveforms. The effects of supply frequency (5 to 200 kHz) at pressure levels that are typical for aircraft (20 to 100 kPa) is examined. Results show that RPDIV steadily decreases with frequency up to 100 kHz where it reaches a plateau. This behavior is explained as an effect of the oscillations that inevitably exist in the applied voltage waveform. Therefore, a conservative estimate of the RPDIV could be achieved by raising the supply frequency well above the operation frequency. In the experiments, the RPDIV is decreasing linearly with pressure. If this behavior could be confirmed for other insulation systems, the design of systems working at pressures typical of aircraft would result relatively easy.
- Subjects :
- Permittivity
Materials science
Acoustics
02 engineering and technology
Impulse (physics)
Electrical insulation
inverter-fed machines
partial discharges
PDIV
RPDIV
Electrical and Electronic Engineering
01 natural sciences
law.invention
Twisted pair
law
Insulation system
0103 physical sciences
0202 electrical engineering, electronic engineering, information engineering
Waveform
010302 applied physics
020208 electrical & electronic engineering
partial discharge
Magnet
Partial discharge
inverter-fed machine
Voltage
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....2e18c856e6ad7bf4f084b109af25afbb