Back to Search
Start Over
Comparison of biosensor platforms in the evaluation of high affinity antibody-antigen binding kinetics
- Source :
- Analytical Biochemistry. :78-96
- Publisher :
- The Authors. Published by Elsevier Inc.
-
Abstract
- The acquisition of reliable kinetic parameters for the characterization of biomolecular interactions is an important component of the drug discovery and development process. While several benchmark studies have explored the variability of kinetic rate constants obtained from multiple laboratories and biosensors, a direct comparison of these instruments' performance has not been undertaken, and systematic factors contributing to data variability from these systems have not been discussed. To address these questions, a panel of ten high-affinity monoclonal antibodies was simultaneously evaluated for their binding kinetics against the same antigen on four biosensor platforms: GE Healthcare's Biacore T100, Bio-Rad's ProteOn XPR36, ForteBio's Octet RED384, and Wasatch Microfluidics's IBIS MX96. We compared the strengths and weaknesses of these systems and found that despite certain inherent systematic limitations in instrumentation, the rank orders of both the association and dissociation rate constants were highly correlated between these instruments. Our results also revealed a trade-off between data reliability and sample throughput. Biacore T100, followed by ProteOn XPR36, exhibited excellent data quality and consistency, whereas Octet RED384 and IBIS MX96 demonstrated high flexibility and throughput with compromises in data accuracy and reproducibility. Our results support the need for a “fit-for-purpose” approach in instrument selection for biosensor studies.
- Subjects :
- 0301 basic medicine
Octet
Kinetics
Biophysics
Antibody Affinity
Optical biosensor
Nanotechnology
Biosensing Techniques
ProteOn
Ligands
01 natural sciences
Biochemistry
Biacore
03 medical and health sciences
Throughput (business)
Molecular Biology
Antibody-antigen interactions
Chemistry
010401 analytical chemistry
MX96
Antibodies, Monoclonal
Reproducibility of Results
Cell Biology
Antigen binding
Receptor–ligand kinetics
0104 chemical sciences
030104 developmental biology
Data quality
Biological system
Biosensor
High affinity antibody
Protein Binding
Subjects
Details
- Language :
- English
- ISSN :
- 00032697
- Database :
- OpenAIRE
- Journal :
- Analytical Biochemistry
- Accession number :
- edsair.doi.dedup.....2d78f62a1d76d889cb81dde4a5847d19
- Full Text :
- https://doi.org/10.1016/j.ab.2016.06.024