Back to Search
Start Over
Low-contrast-dose liver CT using low monoenergetic images with deep learning–based denoising for assessing hepatocellular carcinoma: a randomized controlled noninferiority trial
- Source :
- European Radiology. 33:4344-4354
- Publication Year :
- 2022
- Publisher :
- Springer Science and Business Media LLC, 2022.
-
Abstract
- Low monoenergetic images obtained using noise-reduction techniques may reduce CT contrast media requirements. We aimed to investigate the effectiveness of low-contrast-dose CT using dual-energy CT and deep learning-based denoising (DLD) techniques in patients at high risk of hepatocellular carcinoma (HCC).We performed a prospective, randomized controlled noninferiority trial at a tertiary hospital between June 2019 and August 2020 (NCT04027556). Patients at high risk of HCC were randomly assigned (1:1) to the standard-contrast-dose group or low-contrast-dose group, which targeted a 40% reduction in contrast medium dose based on lean body weight. HCC conspicuity on arterial phase images was the primary endpoint with a noninferiority margin of 0.2. Images were independently assessed by three radiologists; model-based iterative reconstruction (MBIR) images of the standard-contrast-dose group and low monoenergetic (50-keV) DLD images of the low-contrast-dose group were compared using a generalized estimating equation.Ninety participants (age 59 ± 10 years; 68 men) were analyzed. Compared with the standard-contrast-dose group (n = 47), 40% less contrast media was used in the low-contrast-dose group (n = 43) (107.0 ± 17.1 mL vs. 64.5 ± 11.3 mL, p0.001). In the arterial phase, HCC conspicuity on 50-keV DLD images in the low-contrast-dose group was noninferior to that of MBIR images in the standard-contrast-dose group (2.92 vs. 2.56; difference, 0.36; 95% confidence interval, -0.13 to ∞; p = 0.013).The contrast dose in liver CT can be reduced by 40% without impairing HCC conspicuity when using 50-keV and DLD techniques.• In the arterial phase, hepatocellular carcinoma conspicuity on 50-keV deep learning-based denoising images in the low-contrast-dose group was noninferior to that of model-based iterative reconstruction images in the standard-contrast-dose group. • HCC detection was comparable between 50-keV deep learning-based denoising images in the low-contrast-dose group and model-based iterative reconstruction images in the standard-contrast-dose group.
- Subjects :
- Radiology, Nuclear Medicine and imaging
General Medicine
Subjects
Details
- ISSN :
- 14321084
- Volume :
- 33
- Database :
- OpenAIRE
- Journal :
- European Radiology
- Accession number :
- edsair.doi.dedup.....2c9ba3a2f181dfe6b204be3e6790a633