Back to Search Start Over

Development and Validation of HPLC-UV Method for the Determination of Diclofenac in Human Plasma with Application to a Pharmacokinetic Study

Authors :
Görkem Mergen
Gülsüm Gül Arisoy
Emrah Dural
Mustafa Arisoy
Gülin Güvendik
Tülin Söylemezoğlu
[Arisoy, Gulsum Gul -- Dural, Emrah -- Mergen, Gorkem -- Soylemezoglu, Tulin] Ankara Univ, Inst Forens Sci, Dept Forens Toxicol, Ankara, Turkey -- [Dural, Emrah] Cumhuriyet Univ, Dept Pharmaceut Toxicol, Fac Pharm, Ankara, Turkey -- [Mergen, Gorkem] TechKnowledge FZ LLC, Dubai, U Arab Emirates -- [Arisoy, Mustafa] Ankara Univ, Dept Pharmaceut Chem, Fac Pharm, Ankara, Turkey -- [Guvendik, Gulin] Ankara Univ, Dept Pharmaceut Toxicol, Fac Pharm, Ankara, Turkey
Source :
Turkish Journal of Pharmaceutical Sciences, Vol 13, Iss 3, Pp 292-299 (2016)
Publication Year :
2016
Publisher :
Galenos Yayinevi, 2016.

Abstract

WOS: 000396697500002<br />A simple, rapid and reliable high performance liquid chromatography method (HPLC) with ultraviolet detection (UV) was developed and validated according to ICH guidelines, for quantitative analysis and therapeutic drug monitoring of diclofenac sodium (DS) in human plasma. Plasma samples (0.7 mL) were acid hydrolysis by 100 mu L, 1 M hydrochloric acid. Analytes were concentrated from plasma by liquid-liquid extraction with 2 mL ethyl acetate by repeated twice, which allows to obtain good extraction yields (98.75%-99.32%). The separation was achieved by employing C18 analytical column (3.5 mu m particle size, 150 mmx3.9 mm I.D.) under isocratic conditions using acetonitrile and NaH2PO4 mixture (42.5: 57.5, v/v) as mobile phase (pH: 3.16) flow rate of 1.5 mL/min. Naproxen (3 mu g/mL) was used as an internal standard (IS). The DS and IS were detected at 281 nm and eluted at 2.6 and 6.2 min, respectively. Total run time was 7 min. Method showed linearity with very good determination coefficients (r(2)=0.999), over the concentration range of 50 - 1600 ng/mL. Limits of detection (LOD) and quantification (LOQ) were 8.95 ng/mL and 27.12 ng/mL, respectively. Intra-day precision and accuracy were between 0.93-5.27; 1.74-9.81, respectively. Inter-day precision and accuracy were between 2.71-6.64; 2.03-9.16, respectively. This method was successfully applied for determination of DS plasma concentrations during a pharmacokinetic study in healthy volunteers (n=12) after an oral administration of Voltaren (R) 75 mg/tablet and remarkable variations in DS levels were observed. In our study, on the contrary to equivalent doses of DS, the observed significant differences in plasma levels of DS, on 2nd, 4th and 6th hours, can be explained by pharmacokinetic differences, that arise from mainly polymorphisms of CYP2C9 and CYP3A4, which are major enzymes responsible for DS metabolism.

Details

Language :
English
ISSN :
21486247
Volume :
13
Issue :
3
Database :
OpenAIRE
Journal :
Turkish Journal of Pharmaceutical Sciences
Accession number :
edsair.doi.dedup.....2b4e8e1fa83326080a88da85a623e554