Back to Search
Start Over
Residual shunt after percutaneous closure of patent foramen ovale with AMPLATZER occluder devices - influence of anatomic features: a transcranial Doppler and intracardiac echocardiography study
- Source :
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 9(3)
- Publication Year :
- 2013
-
Abstract
- Aims To evaluate the relationship between the anatomic features of the fossa ovalis (FO) and residual right-to-left shunt (RLS) after percutaneous patent foramen ovale (PFO) closure with AMPLATZER PFO occluder devices. Methods and results FO anatomic features were assessed by intracardiac echocardiography in 127 patients with large RLS at contrast-enhanced transcranial colour Doppler (TCCD) undergoing percutaneous PFO closure with an AMPLATZER device. Residual RLS was evaluated by TCCD three and 12 months after the procedure. PFO closure was successful in all but two patients. At TCCD, a significant residual RLS (grade ≥2) was observed in 27 (21.6%) and 17 (13.6%) patients at three and 12 months, respectively. Larger baseline RLS, presence of atrial septal aneurysm, greater longitudinal and transverse FO dimensions, and use of larger devices were associated with significant residual RLS. At multivariate analysis, the presence of atrial septal aneurysm (OR 7.6; 95% CI: 1.38-42.35; p=0.02) and longitudinal FO dimension >20.8 mm (OR 8.5; 95% CI: 1.55-46.95; p=0.014) were identified as independent predictors of significant residual RLS at 12 months. Conclusions Our study suggests that a large FO and the presence of atrial septal aneurysm are independent predictors of persistent residual RLS after PFO closure with AMPLATZER devices.
- Subjects :
- Adult
Male
medicine.medical_specialty
Cardiac Catheterization
Percutaneous
Time Factors
Septal Occluder Device
Ultrasonography, Doppler, Transcranial
Migraine Disorders
Embolism
Hemodynamics
Foramen Ovale, Patent
Prosthesis Design
Predictive Value of Tests
Risk Factors
Internal medicine
mental disorders
medicine
Odds Ratio
Humans
Fossa ovalis
Heart Aneurysm
Ultrasonography, Doppler, Color
business.industry
Middle Aged
medicine.disease
Shunt (medical)
Transcranial Doppler
Stroke
medicine.anatomical_structure
Logistic Models
Treatment Outcome
Echocardiography
Ischemic Attack, Transient
Predictive value of tests
Cerebrovascular Circulation
Multivariate Analysis
Cardiology
Patent foramen ovale
Female
Radiology
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 19696213
- Volume :
- 9
- Issue :
- 3
- Database :
- OpenAIRE
- Journal :
- EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
- Accession number :
- edsair.doi.dedup.....2aea52cf3476b28fb7c85f5a41f35eed