Back to Search Start Over

Accuracy and Cost-effectiveness of Technology-Assisted Dietary Assessment Comparing the Automated Self-administered Dietary Assessment Tool, Intake24, and an Image-Assisted Mobile Food Record 24-Hour Recall Relative to Observed Intake: Protocol for a Randomized Crossover Feeding Study

Authors :
Clare Whitton
Janelle D Healy
Clare E Collins
Barbara Mullan
Megan E Rollo
Satvinder S Dhaliwal
Richard Norman
Carol J Boushey
Edward J Delp
Fengqing Zhu
Tracy A McCaffrey
Sharon I Kirkpatrick
Paul Atyeo
Syed Aqif Mukhtar
Janine L Wright
César Ramos-García
Christina M Pollard
Deborah A Kerr
Source :
JMIR Research Protocols
Publication Year :
2021

Abstract

BACKGROUND The assessment of dietary intake underpins population nutrition surveillance and nutritional epidemiology and is essential to inform effective public health policies and programs. Technological advances in dietary assessment that use images and automated methods have the potential to improve accuracy, respondent burden, and cost; however, they need to be evaluated to inform large-scale use. OBJECTIVE The aim of this study is to compare the accuracy, acceptability, and cost-effectiveness of 3 technology-assisted 24-hour dietary recall (24HR) methods relative to observed intake across 3 meals. METHODS Using a controlled feeding study design, 24HR data collected using 3 methods will be obtained for comparison with observed intake. A total of 150 healthy adults, aged 18 to 70 years, will be recruited and will complete web-based demographic and psychosocial questionnaires and cognitive tests. Participants will attend a university study center on 3 separate days to consume breakfast, lunch, and dinner, with unobtrusive documentation of the foods and beverages consumed and their amounts. Following each feeding day, participants will complete a 24HR process using 1 of 3 methods: the Automated Self-Administered Dietary Assessment Tool, Intake24, or the Image-Assisted mobile Food Record 24-Hour Recall. The sequence of the 3 methods will be randomized, with each participant exposed to each method approximately 1 week apart. Acceptability and the preferred 24HR method will be assessed using a questionnaire. Estimates of energy, nutrient, and food group intake and portion sizes from each 24HR method will be compared with the observed intake for each day. Linear mixed models will be used, with 24HR method and method order as fixed effects, to assess differences in the 24HR methods. Reporting bias will be assessed by examining the ratios of reported 24HR intake to observed intake. Food and beverage omission and intrusion rates will be calculated, and differences by 24HR method will be assessed using chi-square tests. Psychosocial, demographic, and cognitive factors associated with energy misestimation will be evaluated using chi-square tests and multivariable logistic regression. The financial costs, time costs, and cost-effectiveness of each 24HR method will be assessed and compared using repeated measures analysis of variance tests. RESULTS Participant recruitment commenced in March 2021 and is planned to be completed by the end of 2021. CONCLUSIONS This protocol outlines the methodology of a study that will evaluate the accuracy, acceptability, and cost-effectiveness of 3 technology-enabled dietary assessment methods. This will inform the selection of dietary assessment methods in future studies on nutrition surveillance and epidemiology. CLINICALTRIAL Australian New Zealand Clinical Trials Registry ACTRN12621000209897; https://tinyurl.com/2p9fpf2s INTERNATIONAL REGISTERED REPORT DERR1-10.2196/32891

Details

ISSN :
19290748
Volume :
10
Issue :
12
Database :
OpenAIRE
Journal :
JMIR research protocols
Accession number :
edsair.doi.dedup.....2ab37d666524279fe345a4d8038c44d4