Back to Search
Start Over
Assessment of Fit on Ten Screw-Retained FrameworksRealized through Digital Full-Arch Implant Impression
- Source :
- Applied Sciences, Vol 11, Iss 5617, p 5617 (2021), Applied Sciences, Volume 11, Issue 12
- Publication Year :
- 2021
- Publisher :
- MDPI AG, 2021.
-
Abstract
- Background: Discordant opinions have emerged among clinicians and researchers regarding a digital impression for full-arch implant-supported fixed dental prostheses (FDPs). The purpose of this study was to assess the fit of screw-retained milled frameworks on six implants realized from digital impressions through the Sheffield test. Methods: One patient received a maxillary full-arch implant-supported FDP. Six months after the surgical procedure, ten intraoral full-arch digital impressions were performed to mill ten frameworks. To clinically assess the fit, the Sheffield test was applied for all frameworks. The gaps among the frameworks and the implant analogs were measured using a microscope on the master model realized with a traditional impression. The Wilcoxon sum-rank test was used to compare the misfit value among the different implant positions. Results: The Sheffield test did not show gaps in the framework–implant interfaces when the screw was completely tightened on the more distal implant for all the milled frameworks. The mean misfit value calculated after microscope examination was 38 ± 5 μm. Differences that were statistically significant emerged when the misfit values of central positions were compared with other values. Conclusions: The use of full-arch implant digital impressions represents a viable alternative to traditional impressions for the fabrication of implant-supported FDPs.
- Subjects :
- Technology
Wilcoxon signed-rank test
Dental implant
QH301-705.5
QC1-999
medicine.medical_treatment
Digital impression
CAD/CAM
Full-arch
Intraoral scanner
03 medical and health sciences
0302 clinical medicine
medicine
General Materials Science
intraoral scanner
Biology (General)
Arch
030223 otorhinolaryngology
QD1-999
Instrumentation
full-arch
Fluid Flow and Transfer Processes
Orthodontics
dental implant
Physics
Process Chemistry and Technology
General Engineering
030206 dentistry
Engineering (General). Civil engineering (General)
Computer Science Applications
Impression
Screw retained
Chemistry
digital impression
Implant
TA1-2040
Psychology
Subjects
Details
- ISSN :
- 20763417
- Volume :
- 11
- Database :
- OpenAIRE
- Journal :
- Applied Sciences
- Accession number :
- edsair.doi.dedup.....2a8fc7f4c913cc4c12e3370b9240a8e7
- Full Text :
- https://doi.org/10.3390/app11125617