Back to Search
Start Over
Titanium Nickelide in Midface Fractures Treatment
- Source :
- Journal of Functional Biomaterials, Volume 11, Issue 3, Journal of Functional Biomaterials, Vol 11, Iss 52, p 52 (2020)
- Publication Year :
- 2020
- Publisher :
- Multidisciplinary Digital Publishing Institute, 2020.
-
Abstract
- Background: The question of reconstruction of human tissues and organs with the use of medical materials is still open, because of the accurate requirements for their biological and physical features. The aim of this study was to prove the efficiency of titanium nickelide constructors in treatment of isolated orbital floor fractures or combination with zygomatico-orbital complex fractures. Methods: Patients with a fracture of zygomatico-orbital complex and/or low orbital floor (n = 44) carried out different treatments: in the first group, osteosynthesis and endoprosthesis with titanium nickelide structures<br />in the second group, titan mini-plates osteosynthesis<br />in the third group (&lsquo<br />blow-out&rsquo<br />), endoprosthesis with a titanium nickelide mesh<br />and in the fourth group (&lsquo<br />), conservative treatment and monitoring (archive data) (p &gt<br />0.05). The paraesthesia, diplopia, enophthalmos and exophthalmos degree were measured in points. Results: In one year, the first and second groups had no differences in level of paraesthesia (p &gt<br />0.05). The absence of exophthalmos and differences between first and second groups, and between the third and the fourth groups with positive dynamics inside the groups were proved (p &lt<br />0.05). In the first and third groups, enophthalmos was absent, and it increased in the second and fourth groups (p &lt<br />0.01, p &lt<br />0.11). Diplopia in the first and third groups was absent, and it increased in the second and fourth groups (p &lt<br />0.05, p &lt<br />0.01). Conclusion: The elasticity and biocompatibility of titanium nickelide make the implant insertion and restoration of the lower orbital wall anatomy easier, with good postoperative clinical results.
- Subjects :
- Materials science
Exophthalmos
genetic structures
lcsh:Biotechnology
Titanium nickelide
Biomedical Engineering
Article
orbital floor
Biomaterials
03 medical and health sciences
0302 clinical medicine
titanium nickelide
lcsh:TP248.13-248.65
medicine
endoprosthesis
Orthodontics
Diplopia
lcsh:R5-920
Orbital wall
Osteosynthesis
Enophthalmos
Zygoma fracture
030206 dentistry
eye diseases
030220 oncology & carcinogenesis
Implant
medicine.symptom
midface fracture
lcsh:Medicine (General)
zygoma fracture
Subjects
Details
- Language :
- English
- ISSN :
- 20794983
- Database :
- OpenAIRE
- Journal :
- Journal of Functional Biomaterials
- Accession number :
- edsair.doi.dedup.....28abbfd902067d804e7e3453fe82bafb
- Full Text :
- https://doi.org/10.3390/jfb11030052