Back to Search Start Over

Stochastic Optimization of PQ Powers at the Interface between Distribution and Transmission Grids

Authors :
Frederic Colas
Xavier Guillaud
Jean-Yves Dieulot
Jerome Buire
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
Laboratoire d'Électrotechnique et d'Électronique de Puissance (L2EP) - ULR 2697
Centre de Recherche en Informatique, Signal et Automatique de Lille - UMR 9189 [CRIStAL]
Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 (L2EP)
Centrale Lille-Université de Lille-Arts et Métiers Sciences et Technologies
HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)-HESAM Université - Communauté d'universités et d'établissements Hautes écoles Sorbonne Arts et métiers université (HESAM)-JUNIA (JUNIA)
Université catholique de Lille (UCL)-Université catholique de Lille (UCL)
Centre de Recherche en Informatique, Signal et Automatique de Lille - UMR 9189 (CRIStAL)
Centrale Lille-Université de Lille-Centre National de la Recherche Scientifique (CNRS)
Centrale Lille-Haute Etude d'Ingénieurs-Université de Lille-Arts et Métiers Sciences et Technologies
HESAM Université (HESAM)-HESAM Université (HESAM)
Source :
Energies, Volume 12, Issue 21, Energies, 2019, 12 (21), pp.4057, HAL, Energies, MDPI, 2019, 12 (21), pp.4057, Energies, Vol 12, Iss 21, p 4057 (2019)
Publication Year :
2019
Publisher :
MDPI, 2019.

Abstract

International audience; This paper addresses the volt-var control of distribution grids embedding many distributed generators (DGs). Specifically, it focuses on the compliance of powers to specified PQ diagrams at the high voltage/medium voltage (HV/MV) interface while the voltages remain well controlled. This is achieved using a two-stage optimization corresponding to two different classes of actuators. The tap position of capacitor banks is selected on a daily basis, given a stochastic model of the input powers prediction, which allows infrequent actuation and increases the device lifespan. In a second stage, a confidence level optimization problem allows to tune on an hourly basis the parameters of the DGs reactive power affine control laws. Results on a real-size grid show that the combined tuning of these actuators allows the ability to comply with European grid codes while the control effort remains reasonable.

Details

Language :
English
ISSN :
19961073
Database :
OpenAIRE
Journal :
Energies, Volume 12, Issue 21, Energies, 2019, 12 (21), pp.4057, HAL, Energies, MDPI, 2019, 12 (21), pp.4057, Energies, Vol 12, Iss 21, p 4057 (2019)
Accession number :