Back to Search
Start Over
Counting train-of-four twitch response: comparison of palpation to mechanomyography, acceleromyography, and electromyography
- Source :
- British journal of anaesthesia. 124(6)
- Publication Year :
- 2019
-
Abstract
- Background Train-of-four twitch monitoring can be performed using palpation of thumb movement, or by the use of a more objective quantitative monitor, such as mechanomyography, acceleromyography, or electromyography. The relative performance of palpation and quantitative monitoring for determination of the train-of-four ratio has been studied extensively, but the relative performance of palpation and quantitative monitors for counting train-of-four twitch responses has not been completely described. Methods We compared train-of-four counts by palpation to mechanomyography, acceleromyography (Stimpod™), and electromyography (TwitchView Monitor™) in anaesthetised patients using 1691 pairs of measurements obtained from 46 subjects. Results There was substantial agreement between palpation and electromyography (kappa = 0.80), mechanomyography (kappa = 0.67), or acceleromyography (kappa = 0.63). Electromyography with TwitchView and mechanomyography most closely resembled palpation, whereas acceleromyography with StimPod often underestimated train-of-four count. With palpation as the comparator, acceleromyography was more likely to measure a lower train-of-four count, with 36% of counts less than palpation, and 3% more than palpation. For mechanomyography, 31% of train-of-four counts were greater than palpation, and 9% were less. For electromyography, 15% of train-of-four counts were greater than palpation, and 12% were less. The agreement between acceleromyography and electromyography was fair (kappa = 0.38). For acceleromyography, 39% of train-of-four counts were less than electromyography, and 5% were more. Conclusions Acceleromyography with the StimPod frequently underestimated train-of-four count in comparison with electromyography with TwitchView.
- Subjects :
- Adult
Male
medicine.medical_specialty
Electromyography
Thumb
Palpation
03 medical and health sciences
0302 clinical medicine
Physical medicine and rehabilitation
030202 anesthesiology
Accelerometry
medicine
Humans
Aged
medicine.diagnostic_test
business.industry
Myography
Reproducibility of Results
Middle Aged
Neuromuscular monitoring
Anesthesiology and Pain Medicine
medicine.anatomical_structure
Female
business
Subjects
Details
- ISSN :
- 14716771
- Volume :
- 124
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- British journal of anaesthesia
- Accession number :
- edsair.doi.dedup.....281620b5a4a94228a7d8811648555283