Back to Search
Start Over
Cytocompatibility and mechanical properties of surgical sealants for cardiovascular applications
- Source :
- The Journal of thoracic and cardiovascular surgery. 157(1)
- Publication Year :
- 2018
-
Abstract
- Objectives The present study compared physical, mechanical, and biologic characteristics of 4 clinically available surgical sealants for cardiovascular repair. Methods BioGlue (Cryolife Inc, Kennesaw, Ga), PreveLeak (Mallinckrodt Pharmaceuticals, St Louis, Mo), Tridyne VS (BD, Franklin Lakes, NJ), and Coseal (Baxter Healthcare Corporation, Westlake Village, Calif) were compared for the following properties: hydrated swelling, cytocompatibility, burst strength, biaxial stretching (elasticity), and in vitro degradation. Results Sealants showed a wide range of swelling upon hydration. By gravimetric and volumetric measurement, swelling was greatest for Coseal followed by Tridyne VS, BioGlue, and PreveLeak. Tridyne VS was the most cytocompatible based on Alamar Blue assay results, supporting 85% cell survival compared with 36% to 39% survival with the other sealants. All sealants withstood pressure above mean arterial pressure (70-110 mm Hg) and physiologic systolic blood pressure (90-140 mm Hg) in an ex vivo arterial flow burst model; lowest peak pressure at failure was PreveLeak at 235 ± 48 mm Hg, and highest peak pressure at failure was BioGlue at 596 ± 72 mm Hg. Biaxial tensile testing showed no differences in elasticity between ex vivo porcine aorta and carotid arteries and Tridyne VS or Coseal, and BioGlue and PreveLeak were significantly stiffer. In vitro degradation time for Coseal was 6 days and 21 days for Tridyne VS. No degradation was observed in BioGlue or PreveLeak for 30 days. Conclusions Although all sealants withstood supraphysiologic arterial pressure, there were differences in characteristics that may be important in clinical outcome. Coseal degradation time was short compared with other sealants, whereas BioGlue and PreveLeak showed a significant compliance mismatch with native porcine carotid artery. Tridyne VS was significantly more cytocompatible than the other 3 sealants.
- Subjects :
- Pulmonary and Respiratory Medicine
Mean arterial pressure
business.operation
Swine
Peak pressure
Hemorrhage
Biocompatible Materials
030204 cardiovascular system & hematology
Article
Polyethylene Glycols
03 medical and health sciences
0302 clinical medicine
Tensile Strength
medicine
Pressure
Animals
Humans
Aorta
Mechanical Phenomena
Hemostasis
Compliance mismatch
business.industry
Sealant
Cardiovascular Surgical Procedures
Proteins
Mallinckrodt
Elasticity
Blood pressure
Carotid Arteries
030228 respiratory system
Arterial flow
Anesthesia
Surgery
Tissue Adhesives
Swelling
medicine.symptom
Cardiology and Cardiovascular Medicine
business
Subjects
Details
- ISSN :
- 1097685X
- Volume :
- 157
- Issue :
- 1
- Database :
- OpenAIRE
- Journal :
- The Journal of thoracic and cardiovascular surgery
- Accession number :