Back to Search Start Over

TEM10 homodyne detection as an optimal small-displacement and tilt-measurement scheme

Authors :
Mikael Lassen
Hans-A. Bachor
Claude Fabre
Ping Koy Lam
Nicolas Treps
Vincent Delaubert
Charles C. Harb
Laboratoire Kastler Brossel (LKB (Jussieu))
Université Pierre et Marie Curie - Paris 6 (UPMC)-Fédération de recherche du Département de physique de l'Ecole Normale Supérieure - ENS Paris (FRDPENS)
École normale supérieure - Paris (ENS Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS Paris)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Centre National de la Recherche Scientifique (CNRS)
Arc Centre of Excellence for Quantum-Atom Optics (ACQAO)
Australian National University (ANU)
Department of Physics [Lyngby]
Technical University of Denmark [Lyngby] (DTU)
Fédération de recherche du Département de physique de l'Ecole Normale Supérieure - ENS Paris (FRDPENS)
École normale supérieure - Paris (ENS-PSL)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-École normale supérieure - Paris (ENS-PSL)
Université Paris sciences et lettres (PSL)-Université Paris sciences et lettres (PSL)-Centre National de la Recherche Scientifique (CNRS)-Université Pierre et Marie Curie - Paris 6 (UPMC)-Centre National de la Recherche Scientifique (CNRS)
Danmarks Tekniske Universitet = Technical University of Denmark (DTU)
Source :
Delaubert, V, Treps, N, Lassen, M Ø, Harb, C, Fabre, C, Lam, P K & Bachor, H A 2006, ' TEM10 homodyne detection as an optimal small-displacement and tilt-measurement scheme ', Physical Review A, vol. 74, no. 5, pp. 053823 . https://doi.org/10.1103/PhysRevA.74.053823
Publication Year :
2006

Abstract

We report an experimental demonstration of optimal measurements of small displacement and tilt of a Gaussian beam - two conjugate variables - involving a homodyne detection with a TEM10 local oscillator. We verify that the standard split detection is only 64% efficient. We also show a displacement measurement beyond the quantum noise limit, using a squeezed vacuum TEM10 mode within the input beam.<br />9 pages, 8 figures

Details

Language :
English
Database :
OpenAIRE
Journal :
Delaubert, V, Treps, N, Lassen, M Ø, Harb, C, Fabre, C, Lam, P K & Bachor, H A 2006, ' TEM10 homodyne detection as an optimal small-displacement and tilt-measurement scheme ', Physical Review A, vol. 74, no. 5, pp. 053823 . https://doi.org/10.1103/PhysRevA.74.053823
Accession number :
edsair.doi.dedup.....27bc32329f2a47dac8068e92d7b157a5
Full Text :
https://doi.org/10.1103/PhysRevA.74.053823