Feasibility and characterization of a safe susceptibility‐matched endorectal coil for MR spectroscopy

Authors :
Cécile Rabrait-Lerman
Isabelle Saniour
Olivier Beuf
Jean-Marie Verret
Frank Pilleul
Beuf, Olivier
RMN et optique : De la mesure au biomarqueur
Centre de Recherche en Acquisition et Traitement de l'Image pour la Santé (CREATIS)
Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Université de Lyon-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Hospices Civils de Lyon (HCL)-Université Jean Monnet - Saint-Étienne (UJM)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Institut National des Sciences Appliquées (INSA)-Institut National des Sciences Appliquées (INSA)-Hospices Civils de Lyon (HCL)-Université Jean Monnet - Saint-Étienne (UJM)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Centre National de la Recherche Scientifique (CNRS)
General Electric Medical Systems [Buc] (GE Healthcare)
General Electric Medical Systems
Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université de Lyon-Institut National des Sciences Appliquées (INSA)-Université Claude Bernard Lyon 1 (UCBL)
Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)-Université Jean Monnet [Saint-Étienne] (UJM)-Hospices Civils de Lyon (HCL)-Institut National des Sciences Appliquées de Lyon (INSA Lyon)
Université de Lyon-Centre National de la Recherche Scientifique (CNRS)-Institut National de la Santé et de la Recherche Médicale (INSERM)
Source :
NMR in Biomedicine, NMR in Biomedicine, 2020, 33 (11), ⟨10.1002/nbm.4384⟩, NMR in Biomedicine, Wiley, 2020, 33 (11), ⟨10.1002/nbm.4384⟩
Publication Year :
2020
Publisher :
HAL CCSD, 2020.

Abstract

When using endorectal coils, local radiofrequency (RF) heating may occur in the surrounding tissue. Furthermore, most endorectal coils create a susceptibility artifact detrimental to both anatomical magnetic resonance imaging (MRI) and spectroscopy (MRS) acquisitions. We aimed at assessing the safety and MRS performance of a susceptibility-matched endorectal coil for further rectal wall analysis. Experiments were performed on a General Electric MR750 3 T scanner. A variable number of miniaturized passive RF traps were incorporated in the reception cable. The assessment of RF heating and coil sensitivity was conducted on a 1.5% agar-agar phantom doped with NaCl. Several susceptibility-matched materials such as Ultem, perfluorocarbon and barium sulfate were then compared with an external coil. Finally, Ultem was used as a solid support for an endorectal coil and compared with a reference coil. Phantom experiments exhibited a complete suppression of both the RF heating phenomenon and the coil sensitivity artifact. Ultem was the material that produced the smallest image distortion. The full width at half maximum of MR spectra acquired using the susceptibility-matched endorectal coil showed at least 30% narrowing compared with a reference endorectal coil. A susceptibility-matched endorectal coil with RF traps incorporated was validated on phantoms. This coil appears to be a promising device for future in vivo experiments.