Back to Search Start Over

New method for the analysis of process rotating machine shop vibration test

Authors :
A Almasi
Source :
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. 225:217-220
Publication Year :
2011
Publisher :
SAGE Publications, 2011.

Abstract

Factory approval test (FAT) or shop run test is a unique opportunity to evaluate rotating machine performance before delivery to site. This note presents a new adaptive signal processing method to evaluate vibration measurement during FAT based on obtained noisy data. It is also a necessary step for machine reliability, fault diagnosis, future predictive maintenance, and condition monitoring.

Details

ISSN :
20413009 and 09544089
Volume :
225
Database :
OpenAIRE
Journal :
Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Accession number :
edsair.doi.dedup.....26a88d9160fa236cdae1cb489f0eea1a
Full Text :
https://doi.org/10.1243/09544089jpme393430