- Background: 1α,25-Dihydroxyvitamin D [1,25(OH)2 vitD] is the bioactive form of vitamin D. Due to the very low concentrations of 1,25(OH)2 vitD in the blood and its lipophilic character, measurement of this parameter is analytically challenging. Requiring preceding manual extraction steps before analysis, previous assays have been laborious. Methods: In the presented study, we evaluated the performance of two immunoassays from DiaSorin and from Immunodiagnostic Systems (IDS) which combine fully automated extraction and measurement of 1,25(OH)2 vitD. Imprecision and linearity were verified according to Clinical and Laboratory Standards Institute EP15-A3 and EP6-A guidelines, respectively. Ninety-three patient serum samples sent to our institute for determination of 1,25(OH)2 vitD, as well as 20 Vitamin D External Quality Assessment Scheme (DEQAS) samples, were used to evaluate correlation and agreement of 1,25(OH)2 vitD measurements between the two immunoassays and with liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Results: Total imprecision was 5.2% or less for the DiaSorin test but reached 20.1% for the IDS iSYS test. 1,25(OH)2 vitD concentrations measured with the DiaSorin assay showed a strong correlation with 1,25(OH)2 vitD levels measured by LC-MS/MS and a good agreement with method specific means of DEQAS samples. By contrast, the IDS iSYS test overestimated 1,25(OH)2 vitD concentrations in human serum, particularly at higher concentrations. Conclusions: Due to its high sensitivity, low imprecision, broad measurement range, and good agreement with 1,25(OH)2 vitD concentrations measured by LC-MS/MS, the DiaSorin test is a valuable analytical option for the determination of 1,25(OH)2 vitD.
- Subjects :
- 0301 basic medicine
Clinical Biochemistry
610 Medicine & health
1308 Clinical Biochemistry
2704 Biochemistry (medical)
Tandem mass spectrometry
03 medical and health sciences
Automation
Calcitriol
Tandem Mass Spectrometry
540 Chemistry
External quality assessment
Lc ms ms
medicine
Humans
10038 Institute of Clinical Chemistry
1α 25 dihydroxyvitamin d
Immunoassay
Chromatography
medicine.diagnostic_test
Biochemistry (medical)
General Medicine
Serum samples
Manual extraction
030104 developmental biology
Fully automated
Chromatography, Liquid
Subjects
Details
- ISSN :
- 14374331
- Volume :
- 55
- Issue :
- 9
- Database :
- OpenAIRE
- Journal :
- Clinical chemistry and laboratory medicine
- Accession number :
- edsair.doi.dedup.....2677146cd9ac143e28bef6a31796fadc