Back to Search
Start Over
Real-time MR artifacts filtering during continuous EEG/fMRI acquisition
- Publication Year :
- 2003
- Publisher :
- Editore attuale: Kidlington Oxford, United Kingdom: Elsevier Science Limited -primo editore: New York: Pergamon Press, 2003.
-
Abstract
- The purpose of this study was the development of a real-time filtering procedure of MRI artifacts in order to monitor the EEG activity during continuous EEG/fMRI acquisition. The development of a combined EEG and fMRI technique has increased in the past few years. Preliminary "spike-triggered" applications have been possible because in this method, EEG knowledge was only necessary to identify a trigger signal to start a delayed fMRI acquisition. In this way, the two methods were used together but in an interleaved manner. In real simultaneous applications, like event-related fMRI study, artifacts induced by MRI events on EEG traces represent a substantial obstacle for a right analysis. Up until now, the methods proposed to solve this problem are mainly based on procedures to remove post-processing artifacts without the possibility to control electrophysiological behavior of the patient during fMRI scan. Moreover, these methods are not characterized by a strong "prior knowledge" of the artifact, which is an imperative condition to avoid any loss of information on the physiological signals recovered after filtering. In this work, we present a new method to perform simultaneous EEG/fMRI study with real-time artifacts filtering characterized by a procedure based on a preliminary analytical study of EPI sequence parameters-related EEG-artifact shapes. Standard EEG equipment was modified in order to work properly during ultra-fast MRI acquisitions. Changes included: high-performance acquisition device; electrodes/cap/wires/cables materials and geometric design; shielding box for EEG signal receiver; optical fiber link; and software. The effects of the RF pulse and time-varying magnetic fields were minimized by using a correct head cap wires-locked environment montage and then removed during EEG/fMRI acquisition with a subtraction algorithm that takes in account the most significant EPI sequence parameters. The on-line method also allows a further post-processing utilization.
- Subjects :
- Computer science
Biomedical Engineering
Biophysics
Electroencephalography
EEG-fMRI
Signal
Electroencephalograph (EEG)
Software
medicine
Humans
Radiology, Nuclear Medicine and imaging
Computer vision
Functional MRI
Artifact (error)
Signal processing
medicine.diagnostic_test
Echo-Planar Imaging
business.industry
Subtraction
Real-time filtering
Signal Processing, Computer-Assisted
Magnetic Resonance Imaging
Functional MRI, Electroencephalograph (EEG), Real-time filtering
Eeg activity
Artificial intelligence
Artifacts
business
electroencephalograph (eeg)
functional mri
real-time filtering
Algorithms
Subjects
Details
- Language :
- English
- Database :
- OpenAIRE
- Accession number :
- edsair.doi.dedup.....2402eda7b035af34419676182df3ec9d