Back to Search Start Over

Structural Characteristics of Welded Built-up Square Concrete Filled Tubular Stub Columns Associated with Concrete Strength

Authors :
Sung Mo Choi
Sung-Goo Kim
Y.A. Won
Su Hyon Lee
J.S. Bang
Source :
Procedia Engineering. 14:1140-1148
Publication Year :
2011
Publisher :
Elsevier BV, 2011.

Abstract

Thin Walled Cold-Formed Concrete Filled Tubular Square Column are manufactured by flare welding at center of column width for cold formed L shape plates of 4 piece and improved composite effect of concrete and steel by vertical inner anchor. Also, Axial resistance of concrete is increased by confine effect of steel tube and steel prevent local buckling of steel column. In this study, we introduced manufacture method of thin walled cold-formed square column steel square concrete filled tubular column and structural performance of the welded built-up square stub column was verified by structural test for ten specimens with parameters of concrete strength, type of steel tube, width to thickness ratio of steel tube.

Details

ISSN :
18777058
Volume :
14
Database :
OpenAIRE
Journal :
Procedia Engineering
Accession number :
edsair.doi.dedup.....237161145dd4b7d37a8a0706748a1b8d
Full Text :
https://doi.org/10.1016/j.proeng.2011.07.143