Back to Search
Start Over
Sensor-based foot-mounted wearable system and pressure sensitive gait analysis Agreement in frail elderly people in long-term care
- Source :
- Zeitschrift für Gerontologie und Geriatrie, 50(6), 488-497. Springer
- Publication Year :
- 2017
- Publisher :
- Springer, 2017.
-
Abstract
- Background. The RehaWatch (R) system is a portable accelerometer for measurement of gait parameters that shows good validity in young adults; however, validity data are missing for elderly persons in long-term care (LTC).Aim. The aim was to evaluate the concurrent validity of the RehaWatch (R) system using the GAITRite (R) system as a criterion reference for gait assessment in the LTC elderly.Material and methods. In this study 23 elderly participants (mean age 90.9 +/- 8.4 years) performed 4 walking trials at normal and fast walking speed during single task and dual task walking. Data for both systems were collected simultaneously for each trial. Concurrent validity was assessed through limits of agreement (LoA) methodology using Bland-Altman plots.Results. No systematic bias could be determined. Mean biases for step duration, velocity and cadence were above the prespecified +/- 7 % value from zero lines for normal walking during single task and dual task walking. The LoA had a wide range between -21 % and 25 %. Only cadence showed small LoA for normal walking speed during single (-8.4 % to 7.7 %) and dual tasking (-4.1 % to 3 %). Heterogeneous bias was determined for step duration during fast walking during dual task and for velocity during fast walking during single task and dual task. Heteroscedasticity was shown for step length during normal walking under the dual task condition and fast walking during single task and dual task activities.Conclusion. No gait parameters are interchangeably usable between the two systems for normal walking during single task and dual task activities.
- Subjects :
- Male
Reproducibility of results
030506 rehabilitation
Health (social science)
Computer science
Wearable computer
Accelerometer
Task (project management)
Weight-Bearing
Disability Evaluation
0302 clinical medicine
Gait (human)
GAITRITE(R) WALKWAY SYSTEM
Homes for the Aged
Attention
Prospective Studies
Gait
Aged, 80 and over
Data accuracy
RANDOMIZED CONTROLLED-TRIAL
Task performance and analysis
ACCELEROMETRY
Female
TEST-RETEST RELIABILITY
0305 other medical science
Cadence
WALKING
Locomotion
medicine.medical_specialty
Concurrent validity
PARAMETERS
Wearable Electronic Devices
03 medical and health sciences
Physical medicine and rehabilitation
medicine
Humans
Disabled Persons
DIAGNOSTIC-ACCURACY
OLDER-ADULTS
QUANTIFICATION
Frail elderly
Nursing Homes
Preferred walking speed
Issues, ethics and legal aspects
Gait analysis
Physical therapy
Geriatrics and Gerontology
CONCURRENT VALIDITY
Gerontology
030217 neurology & neurosurgery
Subjects
Details
- Language :
- English
- ISSN :
- 14351269 and 09486704
- Volume :
- 50
- Issue :
- 6
- Database :
- OpenAIRE
- Journal :
- Zeitschrift für Gerontologie und Geriatrie
- Accession number :
- edsair.doi.dedup.....223187186355b193d20287355f2f3bce