Back to Search
Start Over
MRI geometric distortion: Impact on tangential whole‐breast IMRT
- Source :
- Journal of Applied Clinical Medical Physics
- Publication Year :
- 2016
- Publisher :
- John Wiley and Sons Inc., 2016.
-
Abstract
- The purpose of this study was to determine the impact of magnetic resonance imaging (MRI) geometric distortions when using MRI for target delineation and planning for whole-breast, intensity-modulated radiotherapy (IMRT). Residual system distortions and combined systematic and patient-induced distortions are considered. This retrospective study investigated 18 patients who underwent whole-breast external beam radiotherapy, where both CT and MRIs were acquired for treatment planning. Distortion phantoms were imaged on two MRI systems, dedicated to radiotherapy planning (a wide, closed-bore 3T and an open-bore 1T). Patient scans were acquired on the 3T system. To simulate MRI-based planning, distortion maps representing residual system distortions were generated via deformable registration between phantom CT and MRIs. Patient CT images and structures were altered to match the residual system distortion measured by the phantoms on each scanner. The patient CTs were also registered to the corresponding patient MRI scans, to assess patient and residual system effects. Tangential IMRT plans were generated and optimized on each resulting CT dataset, then propagated to the original patient CT space. The resulting dose distributions were then evaluated with respect to the standard clinically acceptable DVH and visual assessment criteria. Maximum residual systematic distortion was measured to be 7.9 mm (95%
- Subjects :
- Organs at Risk
medicine.medical_specialty
medicine.medical_treatment
geometric distortion
Breast Neoplasms
Residual
Imaging phantom
030218 nuclear medicine & medical imaging
03 medical and health sciences
0302 clinical medicine
Distortion
medicine
Image Processing, Computer-Assisted
Dosimetry
Radiation Oncology Physics
Humans
Radiology, Nuclear Medicine and imaging
External beam radiotherapy
Radiation treatment planning
Radiometry
Instrumentation
Retrospective Studies
Radiation
medicine.diagnostic_test
business.industry
Phantoms, Imaging
Radiotherapy Planning, Computer-Assisted
Magnetic resonance imaging
Radiotherapy Dosage
Magnetic Resonance Imaging
030220 oncology & carcinogenesis
Female
Radiology
Tomography
Radiotherapy, Conformal
business
Nuclear medicine
breast IMRT
Tomography, X-Ray Computed
Subjects
Details
- Language :
- English
- ISSN :
- 15269914
- Volume :
- 17
- Issue :
- 5
- Database :
- OpenAIRE
- Journal :
- Journal of Applied Clinical Medical Physics
- Accession number :